Environmental Specifications

SurePOS 500 4846-XX5 Technical Reference

4.0

Environmental Specifications

 

 

 

 

 

 

 

 

 

 

4.1

Temperature/Humidity Limits

 

 

 

 

 

 

 

 

 

 

Condition

Temp Limits (Dry Bulb)

Relative Humidity

Max. Wet Bulb Temp

 

 

Operating / Standby

5 to 40°

8 to 80 %

27°C

 

 

Storage (packaged)

0 to 60°C

5 to 80 %

29°C

 

 

Shipment (packaged)

-40 to 60°C

5 to 100 %

29°C

 

 

 

 

 

 

4.2

Altitude Limits

 

 

 

The product is designed to operate up to 3050 meters (10,000 feet).

4.3 Power

 

Off (attached to mains)

4W

Power Consumption

Suspend

Not supported

Standby

80W

(system)

On (idle)

120W

 

 

On (max)

170W

Input Voltage

100 - 127, 200 - 240 VAC (nominal), 50 or 60 Hz (+/- 3 Hz)

Sinusoidal, trapezoidal, or square wave inputs

 

kVA

0.3

 

AC Input Connector/Cable

IEC 320 C14, unshielded right angle type

Leakage current

3.5 mA maximum

 

Inrush

< 30 A (peak, first cycle)

 

4.4Acoustics

Measurement

Operator -Idle

LwAu (bels)

5.0

All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296.

4.5Standards Compliance

4.5.1Product Certifications

Category

Standard

 

IEC 60950-1 1st Edition with all national deviations

 

UL 60950-1 1st Edition

 

CAN/CSA C22.2 No. 60950-1 3rd Edition

External Safety

CCC (China)

IRAM (Argentina)

 

PSE (Japan)

 

GOST (Russia)

 

BSMI (Taiwan)

 

 

Electrostatic Discharge (ESD)

EN 55024:1998 (EN 61000-4-2:1995)