![Environmental Specifications](/images/new-backgrounds/112285/11228569x1.webp)
SurePOS 500
4.0 | Environmental Specifications |
|
|
| ||
|
|
|
|
|
|
|
4.1 | Temperature/Humidity Limits |
|
|
| ||
|
|
|
|
|
| |
| Condition | Temp Limits (Dry Bulb) | Relative Humidity | Max. Wet Bulb Temp |
| |
| Operating / Standby | 5 to 40° | 8 to 80 % | 27°C |
| |
| Storage (packaged) | 0 to 60°C | 5 to 80 % | 29°C |
| |
| Shipment (packaged) | 5 to 100 % | 29°C |
| ||
|
|
|
|
| ||
4.2 | Altitude Limits |
|
|
|
The product is designed to operate up to 3050 meters (10,000 feet).
4.3 Power
| Off (attached to mains) | 4W | |
Power Consumption | Suspend | Not supported | |
Standby | 80W | ||
(system) | |||
On (idle) | 120W | ||
| |||
| On (max) | 170W | |
Input Voltage | 100 - 127, 200 - 240 VAC (nominal), 50 or 60 Hz (+/- 3 Hz) | ||
Sinusoidal, trapezoidal, or square wave inputs | |||
| |||
kVA | 0.3 |
| |
AC Input Connector/Cable | IEC 320 C14, unshielded right angle type | ||
Leakage current | 3.5 mA maximum |
| |
Inrush | < 30 A (peak, first cycle) |
|
4.4Acoustics
Measurement | Operator |
LwAu (bels) | 5.0 |
All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296.
4.5Standards Compliance
4.5.1Product Certifications
Category | Standard | |
| • IEC | |
| • UL | |
| • CAN/CSA C22.2 No. | |
External Safety | • | CCC (China) |
• | IRAM (Argentina) | |
| • | PSE (Japan) |
| • | GOST (Russia) |
| • | BSMI (Taiwan) |
|
| |
Electrostatic Discharge (ESD) | EN 55024:1998 (EN |
Page 35 of 63