IBM 600 manual Input Field

Models: 600

1 147
Download 147 pages 10.32 Kb
Page 116
Image 116

Set System Event

2 Condition

 

 

Input Field

 

 

 

Major Function Number - 32

 

Minor Function Number -

1

 

Parameter 1

- Condition for system timer expiration

 

Bits

15-8 - Capability

 

(see

page B-34)

 

Bits

7-

- Condition

 

(see

page B-34)

Parameter 2

- Reserved

Parameter 3

- Reserved

Parameter 4

- Bits 31-16 : Reserved

 

Bits

15-

Condition for standby

 

 

 

timer expired

 

Bits

15-8 - Capability

 

(see

page B-34)

 

Bits

7-

- Condition

 

(see

page B-34)

Parameter 5

- Bits 31-16 : Reserved

 

Bits

15-

Condition for hibernation

 

timer during suspend mode expired

 

Bits

15-8 - Capability

 

(see

page B-34)

 

Bits

7-

- Condition

 

(see

page B-34)

Output Field

 

 

 

Return Code

- Error status

Auxiliary Return Code - Reserved

Parameter 1

- Reserved

Parameter 2

- Reserved

Parameter 3

- Reserved

Parameter 4

- Reserved

Parameter 5

- Reserved

B-40