PC-CARD-DAS16/16AO User's Guide Installing the PC-CARD-DAS16/16AO

Cabling Measurement Computing offers two cables for connecting the PC-CARD-DAS16/16AO to a screw-type terminal board or other signal conditioning interface board: The CPCC-50F-39 cable: 39 inches (990 mm) long; compatible with standard 50-pin screw terminal products. The CPCC-50M-4 cable: four-inch long adapter cable; required when using a C50FF-x series cable.
CPCC-50M-4 cable end
(connect to C50FF-x)
1
50
PC-CARD end
CH0 HI
CH1 HI
CH2 HI
CH3 HI
CH4 HI
CH5 HI
CH6 HI
CH7 HI
AGND
N/C
N/C
N/C
DGND
DIO1
DIO3
DA OUT0
DA OUT1
CTR1 GATE
A/D External Pacer
A/D Pacer Gate
N/C
+5V Power
DGND
N/C
N/C
AGND
CH0 LO
CH1 LO
CH2 LO
CH3 LO
CH4 LO
CH5 LO
CH6 LO
CH7 LO
N/C
N/C
N/C
N/C
DIO0
DIO2
DA GND0
DA GND1
CTR1 CLK
CTR1 OUT
External Interrupt
A/D External Trigger
A/D Pacer Out
N/C
N/C
N/C
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
CPCC-50F-39 cable end
(connect to screw terminal or r elay boards)
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
CH0 HI
CH1 HI
CH2 HI
CH3 HI
CH4 HI
CH5 HI
CH6 HI
CH7 HI
AGND
N/C
N/C
N/C
DGND
DIO1
DIO3
DIO5
DIO7
DA OUT0
DA OUT1
CTR1 GATE
A/D External Pacer
A/D Pacer Gate
N/C
+5V Power
DGND
AGND
CH0 LO
CH1 LO
CH2 LO
CH3 LO
CH4 LO
CH5 LO
CH6 LO
CH7 LO
N/C
N/C
N/C
N/C
DIO0
DIO2
DIO4
DIO6
CTR1 CLK
CTR1 OUT
External Interrupt
A/D External Trigger
A/D Pacer Out
N/C
DA GND0
DA GND1

Figure 4. Differential mode cable map — PC-CARD to CPCC-50M-4 and to CPCC-50F-39

1
50
PC-CARD end
CPCC-50M-4 cable end
(connect to C50FF-x)
CH0 IN
CH1
CH2
CH3
CH4
CH5
CH6
CH7
AGND
N/C
N/C
N/C
DGND
DIO1
DIO3
DIO5
DIO7
DA OUT0
DA OUT1
CTR1 GATE
A/D External Pacer
A/D Pacer Gate
N/C
+5V Power
DGND
IN
IN
IN
IN
IN
IN
IN
AGND
CH8 IN
CH9 IN
CH10 IN
CH11 IN
CH12 IN
CH13 IN
CH14 IN
CH15 IN
N/C
DIO0
DA GND0
DA GND1
CTR1 CLK
CTR1 OUT
External Interrupt
A/D External Trigger
A/D Pacer Out
N/C
N/C
N/C
N/C
DIO2
DIO4
DIO6
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
CPCC-50F-39 cable end
(connect to screw terminal or relay board s)
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
CH0 IN
CH1 IN
CH2 IN
CH3 IN
CH4 IN
CH5 IN
CH6 IN
CH7 IN
AGND
N/C
N/C
N/C
DGND
DIO1
DIO3
DIO5
DIO7
DA OUT0
CTR1 GATE
A/D External Pacer
A/D Pacer Gate
N/C
+5V Power
DGND
DA OUT1
AGND
CH8 IN
CH9 IN
CH10 IN
CH11 IN
CH12 IN
CH13 IN
CH14 IN
CH15 IN
N/C
N/C
N/C
N/C
DIO0
DIO2
DIO4
DIO6
DA GND0
DA GND1
CTR1 CLK
CTR1 OUT
External Interrupt
A/D External Trigger
A/D Pacer Out
N/C

Figure 5. Single-ended mode cable map — PC-CARD to CPCC-50M-4 and to CPCC-50F-39

Note Digital signals should not be grounded to an analog ground (AGND) pin. Use a digital ground (DGND) pin. 13