PC-CARD-DAS16/16AO User's Guide

Installing the PC-CARD-DAS16/16AO

Cabling

Measurement Computing offers two cables for connecting the PC-CARD-DAS16/16AO to a screw-type terminal board or other signal conditioning interface board:

ƒThe CPCC-50F-39 cable: 39 inches (990 mm) long; compatible with standard 50-pin screw terminal products.

ƒThe CPCC-50M-4 cable: four-inch long adapter cable; required when using a C50FF-x series cable.

 

AGND

1

 

 

 

2

CH0 HI

 

 

 

 

CH0 LO

3

 

 

 

4

CH1 HI

 

 

 

 

 

 

 

CH1 LO

5

 

 

 

6

CH2 HI

 

 

 

1

CH2 LO

7

 

 

 

8

CH3 HI

 

 

 

 

CH3 LO

9

 

 

 

10

CH4 HI

 

 

 

 

 

CH4 LO

11

 

 

 

12

CH5 HI

 

 

 

 

 

 

 

CH5 LO

13

 

 

 

14

CH6 HI

 

 

 

 

 

 

 

CH6 LO

15

 

 

 

16

CH7 HI

 

 

 

 

CH7 LO

17

 

 

 

18

AGND

 

 

 

 

 

 

 

N/C

19

 

 

 

20

N/C

 

 

 

 

N/C

21

 

 

 

22

N/C

 

 

 

 

N/C

23

 

 

 

24

N/C

 

 

 

 

 

 

 

N/C

25

 

 

 

26

DGND

 

 

 

 

DIO0

27

 

 

 

28

DIO1

 

 

 

 

DIO2

29

 

 

 

30

DIO3

 

 

 

 

N/C

31

 

 

 

32

N/C

 

 

 

 

N/C

33

 

 

 

34

N/C

 

 

 

 

DA GND0

35

 

 

 

36

DA OUT0

 

 

 

 

DA GND1

37

 

 

 

38

DA OUT1

 

 

 

 

CTR1 CLK

39

 

 

 

40

CTR1 GATE

 

 

 

50

CTR1 OUT

41

 

 

 

42

A/D External Pacer

 

 

 

 

PC-CARD end

External Interrupt

43

 

 

 

44

A/D Pacer Gate

A/D External Trigger

45

 

 

 

46

N/C

 

 

 

A/D Pacer Out

47

 

 

 

48

+5V Power

 

 

 

 

N/C

49

 

 

 

50

DGND

 

 

 

CPCC-50M-4 cable end

(connect to C50FF-x)

CH0 HI

2

 

 

 

1

AGND

 

 

CH1 HI

4

 

 

 

3

CH0 LO

 

 

 

 

CH2 HI

6

 

 

 

5

CH1 LO

 

 

CH3 HI

8

 

 

 

7

CH2 LO

 

 

 

 

CH4 HI

10

 

 

 

9

CH3 LO

 

 

CH5 HI

12

 

 

 

11

CH4 LO

 

 

 

 

CH6 HI

14

 

 

 

13

CH5 LO

 

 

 

 

CH7 HI

16

 

 

 

15

CH6 LO

 

 

AGND

18

 

 

 

17

CH7 LO

 

 

 

 

N/C

20

 

 

 

19

N/C

 

 

N/C

22

 

 

 

21

N/C

 

 

N/C

24

 

 

 

23

N/C

 

 

 

 

DGND

26

 

 

 

25

N/C

 

 

DIO1

28

 

 

 

27

DIO0

 

 

DIO3

30

 

 

 

29

DIO2

 

 

DIO5

32

 

 

 

31

DIO4

 

 

DIO7

34

 

 

 

33

DIO6

 

 

DA OUT0

36

 

 

 

35

DA GND0

 

 

DA OUT1

38

 

 

 

37

DA GND1

 

 

CTR1 GATE

40

 

 

 

39

CTR1 CLK

 

 

A/D External Pacer

42

 

 

 

41

CTR1 OUT

 

 

A/D Pacer Gate

44

 

 

 

43

External Interrupt

 

 

N/C

46

 

 

 

45

A/D External Trigger

 

 

+5V Power

48

 

 

 

47

A/D Pacer Out

 

 

DGND

50

 

 

 

49

N/C

 

 

CPCC-50F-39 cable end

(connect to screw terminal or relay boards)

Figure 4. Differential mode cable map — PC-CARD to CPCC-50M-4 and to CPCC-50F-39

 

AGND

1

 

 

 

2

CH0 IN

 

 

 

 

CH8 IN

3

 

 

 

4

CH1 IN

 

 

 

 

 

 

 

CH9 IN

5

 

 

 

6

CH2 IN

 

 

 

1

CH10 IN

7

 

 

 

8

CH3 IN

 

 

 

 

CH11 IN

9

 

 

 

10

CH4 IN

 

 

 

 

 

 

 

 

CH12 IN

11

 

 

 

12

CH5 IN

 

 

 

 

CH13 IN

13

 

 

 

14

CH6 IN

 

 

 

 

 

 

 

CH14 IN

15

 

 

 

16

CH7 IN

 

 

 

 

CH15 IN

17

 

 

 

18

AGND

 

 

 

 

 

 

 

N/C

19

 

 

 

20

N/C

 

 

 

 

N/C

21

 

 

 

22

N/C

 

 

 

 

N/C

23

 

 

 

24

N/C

 

 

 

 

N/C

25

 

 

 

26

DGND

 

 

 

 

DIO0

27

 

 

 

28

DIO1

 

 

 

 

DIO2

29

 

 

 

30

DIO3

 

 

 

 

 

 

 

DIO4

31

 

 

 

32

DIO5

 

 

 

 

DIO6

33

 

 

 

34

DIO7

 

 

 

 

DA GND0

35

 

 

 

36

DA OUT0

 

 

 

 

DA GND1

37

 

 

 

38

DA OUT1

 

 

 

 

CTR1 CLK

39

 

 

 

40

CTR1 GATE

 

 

 

50

CTR1 OUT

41

 

 

 

42

A/D External Pacer

 

 

 

 

PC-CARD end

External Interrupt

43

 

 

 

44

A/D Pacer Gate

 

 

A/D External Trigger

45

 

 

 

46

N/C

 

 

 

A/D Pacer Out

47

 

 

 

48

+5V Power

 

 

 

 

N/C

49

 

 

 

50

DGND

 

 

 

CPCC-50M-4 cable end (connect to C50FF-x)

CH0 IN

2

 

 

 

1

AGND

 

 

CH1 IN

4

 

 

 

3

CH8 IN

 

 

 

 

CH2 IN

6

 

 

 

5

CH9 IN

 

 

CH3 IN

8

 

 

 

7

CH10 IN

 

 

 

 

CH4 IN

10

 

 

 

9

CH11 IN

 

 

 

 

CH5 IN

12

 

 

 

11

CH12 IN

 

 

CH6 IN

14

 

 

 

13

CH13 IN

 

 

 

 

CH7 IN

16

 

 

 

15

CH14 IN

 

 

AGND

18

 

 

 

17

CH15 IN

 

 

 

 

N/C

20

 

 

 

19

N/C

 

 

N/C

22

 

 

 

21

N/C

 

 

N/C

24

 

 

 

23

N/C

 

 

DGND

26

 

 

 

25

N/C

 

 

DIO1

28

 

 

 

27

DIO0

 

 

DIO3

30

 

 

 

29

DIO2

 

 

 

 

DIO5

32

 

 

 

31

DIO4

 

 

DIO7

34

 

 

 

33

DIO6

 

 

DA OUT0

36

 

 

 

35

DA GND0

 

 

DA OUT1

38

 

 

 

37

DA GND1

 

 

CTR1 GATE

40

 

 

 

39

CTR1 CLK

 

 

A/D External Pacer

42

 

 

 

41

CTR1 OUT

 

 

 

 

A/D Pacer Gate

44

 

 

 

43

External Interrupt

 

 

N/C

46

 

 

 

45

A/D External Trigger

 

 

+5V Power

48

 

 

 

47

A/D Pacer Out

 

 

DGND

50

 

 

 

49

N/C

 

 

CPCC-50F-39 cable end

(connect to screw terminal or relay boards)

Figure 5. Single-ended mode cable map — PC-CARD to CPCC-50M-4 and to CPCC-50F-39

Note

Digital signals should not be grounded to an analog ground (AGND) pin. Use a digital ground (DGND) pin.

13

Page 13
Image 13
IBM DAS16AO manual Cabling