ETrbl.fm Page 16 Friday, April 14, 2000 12:57 PM

Problem

Possible Cause

Suggested Action

Reference

 

 

 

 

Screen is blank and

Display mode of the

Reconfigure the computer to use a supported

Further Information on

power indicator is

computer is outside

display mode.

page 12.

flashing green

the range of the

 

 

every 0.3 second.

monitor.

 

 

 

 

 

 

Screen is blank and

The monitor is in the

Press any key on the keyboard or move the

Power Management section on

power indicator is

Power Management

mouse to restore operation.

page 13.

flashing green

Suspend or Off state.

Check the Power Management software on

 

every 1 or 2

 

your computer.

 

seconds.

 

 

 

 

 

 

 

“Check Signal

The monitor is not

Check that the signal cable is firmly connected

Connecting your monitor

receiving a video

to the computer and the monitor.

section on page 2.

Cable” displays on

signal.

Check that no pins are bent in the signal cable

 

the screen.

 

 

connector.

 

 

 

 

 

 

 

 

 

The monitor is

Reconfigure the computer to use a non-

Further Information on

 

operating in an

interlaced display mode with a refresh rate of at

page 12.

 

interlaced or low

least 75 Hz.

 

Image appears to

refresh rate display

 

 

mode.

 

 

be flickering.

 

 

 

The monitor might be

Move fluorescent desk lighting or any

 

 

 

 

affected by

equipment that produces magnetic fields

 

 

interference from

further away from the monitor.

 

 

nearby equipment.

 

 

 

 

 

 