CEMT INQUIRE UOWDSNFAIL DSN(’RLS.ACCOUNTS.ESDS.DBASE1’)

STATUS: RESULTS

 

Dsn(RLS.ACCOUNTS.ESDS.DBASE1

) Dat Del

Uow(AA6DB080C40CEE01)

Rls

Dsn(RLS.ACCOUNTS.ESDS.DBASE1

) Dat Ind

Uow(AA6DB08AC66B4000)

Rls

The display shows a REASON code of DELEXITERROR (Del) for one unit of work, and INDEXRECFULL (Ind) for the other.

2.A CEMT SET DSNAME(...) RETRY command, after fixing the delete exit error (caused because an XFCLDEL exit program was not enabled) invokes a retry of both units of work with the following result:

SET DSNAME(’RLS.ACCOUNTS.ESDS.DBASE1’) RETRY

 

 

STATUS: RESULTS - OVERTYPE TO MODIFY

 

 

 

Dsn(RLS.ACCOUNTS.ESDS.DBASE1

 

) Vsa

NORMAL

Fil(0001) Val Bas Rec Sta

Ava

Ret

 

3.Another CEMT INQ UOWDSNFAIL command shows that one of the two units of work failed again. It is the unit of work with the INDEXRECFULL error, as follows:

INQUIRE

UOWDSNFAIL

 

STATUS:

RESULTS

 

Dsn(RLS.ACCOUNTS.ESDS.DBASE1

) Dat Ind

Uow(AA6DB08AC66B4000) Dat Ind

Rls

This type of error can occur when adding a value to a non-unique alternate index while trying to back out a change to a record; after the original update was made, other units of work have added values to the alternate index, filling all the available space. Such an error should be extremely rare. The solution is to define a larger alternate index record size for the data set.

4.However, the data set with the remaining failed unit of work is needed urgently for a batch run, so you may decide not to complete the unit of work now, and to resolve the problem later. In the meantime, to allow the batch job to start, you issue SET DSN(’RLS.ACCOUNTS.ESDS.DBASE1’) RESETLOCKS to release the retained locks associated with the unit of work.

5.To check that there are no retained locks left, you can issue another INQUIRE DSNAME command. The expanded display shows:

Dsname(RLS.ACCOUNTS.ESDS.DBASE1)

Accessmethod(Vsam)

Action()

Filecount(0001)

Validity(Valid)

Object(Base)

Recovstatus(Recoverable)

Backuptype(Static)

Frlog()

Availability( Available )

Lostlocks()

Retlocks(Noretained)

Quiescestate()

Uowaction()

Basedsname(RLS.ACCOUNTS.ESDS.DBASE1)

Fwdrecovlsn(RLS.ACCOUNTS.FWDRECOV.LOG)

6.Diagnostic messages have been written to the CSFL transient data queue about the locks that were reset.

DFHFC3003 01/04/95 12:08:03 CICSHDA1 Record not backed out because locks for a backout-failed data set have been reset.

Diagnostic information follows in message DFHFC3010. The record was updated by unit of work X’AA6DB08AC66B4000’ for file ACCNT1 , base data set RLS.ACCOUNTS.ESDS.DBASE1

DFHFC3010 01/04/95 12:08:03 CICSHDA1 Diagnostic information for unit of work

Chapter 15. Resolving retained locks on recoverable resources 179