• CONNECTION

Standard signal generator

0.1V to 32 mV (–127 dBm to –17 dBm)

to the antenna connector

to [MIC]

Audio generator

CAUTION:

DO NOT transmit while SSG is connected to the antenna connector.

Personal computer

to an RS-232C port

FM

deviation meter

Attenuator

40 dB or 50 dB

RF power meter 0.1–10 W/50 Ω

Frequency

counter

OPC-478

DB9 female plug

(incl. level converter circuit)

Speaker (8 Ω )

to [SP]

SINAD meter

JIG cable

• DC POWER CABLE CONNECTIONS

SOFTWARE ADJUSTMENT

+

DC POWER

SUPPLY

DC POWER

SUPPLY

Soldering

DC cable here

PLL ADJUSTMENT

+

Top view

5 - 3

Page 14