SOFTWARE ADJUSTMENT – continued

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

MEASUREMENT

VALUE

 

 

 

 

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

RX

1

• Operating frequency: 146.000 MHz

Top

Connect a SINAD meter with an

Minimum distortion

SENSITIVITY

 

• Connect a standard signal generator to

panel

8Ω load to the [SP] jack.

level

[BPF T1] –

 

the antenna connector and set as:

 

 

 

[BPF T4]

 

Frequency

: 146.000 MHz

 

 

 

 

 

 

Level

: 3.2 µV* (–97 dBm)

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

Deviation

: ±3.5 kHz (W-type)

 

 

 

 

 

 

 

±1.75 kHz (N-type)

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

CONVENIENT: The BPF T1–BPF T4 can be adjusted automatically.

q-1: Set the cursol to “BPF ALL” on the adjustment program and then push [ENTER] key.

q-2: The connected PC tunes BPF T1–BPF T4 to peak levels. or

w-1: Set the cursol to one of BPF T1, T2, T3, or T4 as desired.

w-2: Push [ENTER] key to start tuning.

w-3: Repeat w-1 and w-2 to perform additional BPF tuning.

SQUELCH

1

• Operating frequency: 146.000 MHz

Top

Connect a SINAD meter with an

12 dB SINAD

LEVEL

 

• Connect a standard signal generator to

panel

8Ω load to the [SP] jack.

 

[SQL]

 

the antenna connector and set as:

 

 

 

 

 

Frequency

: 146.000 MHz

 

 

 

 

 

Level

: OFF

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

Deviation

: ±3.5 kHz (W-type)

 

 

 

 

 

 

±1.75 kHz (N-type)

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

2

• Receiving

 

 

 

At the point where

 

 

 

 

 

 

the audio signals

 

 

 

 

 

 

just appears.

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

5 - 6