SOFTWARE ADJUSTMENT – continued

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

“SQUELCH LEVEL ADJUSTMENT” must be performed after “RX SENSITIVITY ADJUSTMENT” is finished.

“SQUELCH LEVEL ADJUSTMENT” must be performed when “RX SENSITIVITY ADJUSTMENT” is adjusted.

 

 

 

 

 

ADJUSTMENT CONDITION

 

MEASUREMENT

VALUE

 

ADJUSTMENT

 

 

 

 

 

 

 

 

 

 

 

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

RX

 

1

 

• Operating frequency: center frequency

Top

Connect a SINAD meter with an

Minimum distortion

SENSITIVITY

 

 

 

• Channel spacing

: Wide

panel

8 load to the [SP] jack.

level

[BPF T1]–[BPF T4]

 

 

 

• Connect a standard signal generator to

 

 

 

 

 

 

 

 

 

the antenna connector and set as:

 

 

 

 

 

 

 

 

 

Level

: 10 µV* (–87 dBm)

 

 

 

 

 

 

 

 

 

Modulation

: OFF

 

 

 

 

 

 

 

 

 

Deviation

: ±3.0 kHz

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONVENIENT: The BPF T1–BPF T4 can be adjusted automatically.

 

 

 

 

 

 

 

1: Set the cursor to “BPF ALL” on the adjustment program and then push [ENTER] key.

 

 

 

 

 

 

2: The connected PC tunes BPF T1–BPF T4 to peak levels.

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

1: Set the cursol to one of BPF T1, T2, T3, or T4 as desired.

 

 

 

 

 

 

 

2: Push [ENTER] key to start tuning.

 

 

 

 

 

 

 

3: Repeat w-1 and w-2 to perform additional BPF tuning.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUELCH

 

1

• Operating frequency: center frequency

Top

The “SQUELCH LEVEL” adjustment is adjusted by

LEVEL

 

 

 

• Channel spacing

: Wide

panel

“ADJUSTMENT SOFTWARE”, automatically.

[SQL]

 

 

 

• Connect a standard signal generator to

 

 

 

 

 

 

 

 

 

the antenna connector and set as:

 

 

 

 

 

 

 

 

 

Level

: 0.56 µV* (–112 dBm)

 

 

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

 

 

Deviation

: ±3.0 kHz

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

5 - 6