Icom iF22SR instruction manual Battery Packs, ‘ Battery pack replacement

Models: iF22SR

1 36
Download 36 pages 1.66 Kb
Page 9
Image 9

BATTERY PACKS 2

Battery pack replacement

Before replacing the battery pack, the volume control MUST be ro- tated fully counterclockwise,

until a click is heard, to turn the

power OFF.

• Push the battery release for- ward, then pull the battery pack upward with the trans- ceiver facing you.

DBATTERY PACKS

Charging period

Battery

Voltage

Capacity

 

BC-144,

Operating

pack

 

 

BC-146

BC-119 or

period*

 

 

 

 

 

 

 

 

BC-121

 

 

Battery case for AA

 

 

 

BP-208(R6) 6 alkaline

 

 

 

BP-209

7.2 V

1100

12 hrs

1.5 hrs

14.5 hrs

mAh

 

 

 

 

 

BP-210

7.2 V

1650

18.5 hrs

2 hrs

21.5 hrs

mAh

 

 

 

 

 

BP-222

7.2 V

600

6.5 hrs

1 hr

8 hrs

mAh

 

 

 

 

 

* Operating periods are calculated under the following conditions; Tx : Rx : standby =5 : 5 : 90

Operating period depends on the alkaline cells used. (BP-208 only)

4

Page 9
Image 9
Icom iF22SR instruction manual Battery Packs, ‘ Battery pack replacement