ALLEN&HEATH iLive Reference Guide AP6526 iss.3 51
COPY Hold down COPY then press the SEL or MIX key
associated with the parameters you want to copy. This puts the
parameters on to a ‘clipboard’ to be pasted later. Hold with:
1 Channel or mix SEL key – Copies all the processing associated
with the channel.
Note: The input PREAMP gain, pad and 48V settings are not
copied. The physical input is independent of the channel and may
be associated with other channels too.
2 Processing block SEL key – Copies just the parameters
associated with the selected block, for example a PEQ or Gate. To
copy the GEQ touch the screen SEL button while holding down
COPY.
3 Channel MIX key – Copies the mix settings of one channel to
another including the send levels, stereo send image, assignments
and pre/post settings. Does not copy the fader and mute settings.
4 Output master MIX key – Copies the whole mix from one mix to
another including all channel send levels, stereo send image,
assignments, pre/post settings and global send source.
PASTE Hold down PASTE. The lower toolbar of the TouchScreen
displays information about the parameters currently held on the
clipboard. You can only paste like for like information. The screen
warns you when the operation is not valid. You can paste the
parameters to multiple channels or mixes. While holding down
PASTE, press:
Strip SEL key to paste the whole or partial parameters held on the
clipboard,
Strip MIX key to paste the whole or channel mix parameters held on
the clipboard.
RESET Hold down RESET and then press a strip or processing
block SEL or MIX key to reset its associated parameters to factory
default, for example PEQ or GEQ flat.
Note: Resetting a MIX affects its assignments and send levels
only. It does not change the Pre/Post settings, Source selection or
Mute status.
Reset parameters
Group mix = All assignments off
Aux mix = All ON, Send levels down
Main mix = All ON, Pan centre, Faders down
Matrix = All ON, Send levels down