66 ALLEN&HEATH iLive Reference Guide AP6526 iss.3
Remote B Config Here you configure the way
the MixRack Port B EtherSound ESB network (if
fitted) is set up to work. This configures the
MixRack EtherSound interface cards so that the
slave audio is downstream of the master. In a
linked iLive system where one MixRack has the mic
preamps loaded and another gets its channel
sources from the first via ESB, set the first as the
MASTER and the second as the MASTER/SLAVE.
Note: The ESB config setting remains with the
system. It is remembered on power up. It is not
part of the Scene or Show memories. There is no
indicator to display the current setting. If you are
not sure how it is set simply set it again.
Refer to the Application Diagrams later in this
guide for examples on how to configure the system.
Quick Input Setup Two buttons provide a
convenient way to quickly configure all channel
inputs to get their source from either the local inputs
(normal stand alone system) or the Port B audio
network (linked system slave). This gives you a
starting point for setting your input sources.
Global Remote B Input sets CH 1-64 inputs to get
their sources from Port B channels 1-64. For
example, use this if the MixRack is a slave in a
linked FOH/Monitor or Recording system with
digital mic splitter using EtherSound or ACE.
Global Local Input sets the CH1-64 inputs to get
their sources from the local audio inputs in the
MixRack. It identifies the currently loaded modules
and applies them in the socket order it finds.
Note: Sockets currently assigned as insert
returns are ignored and the associated channel
sources are left unassigned.
Remote B configuration