Image IMHS63100 user manual

Models: IMHS63100

1 20
Download 20 pages 55 Kb
Page 9
Image 9
electrician. A wiring diagram is found on the inside of the electronics pack as a reference. Under no

3. Refer to the drawing on page 6 and locate the

3

 

 

heater access opening.

 

 

Gate

 

 

 

 

 

Locate the two indicated gate valves inside the

Valve

Collar

 

 

 

heater access opening. Make sure that the gate

 

 

 

 

 

valves are open and that the locking clips are

 

 

 

snapped onto the stems of the gate valves (refer to

 

 

 

the inset drawing in step 2 on page 8).

 

 

 

Make sure that the four indicated collars are tight-

 

Collar

Gate

ened.

Collar

 

Valve

Refer to step 1. Re-attach the heater Access Panel

 

Electronics Pack

 

 

 

 

(5) to the spa with the four 1/4” x 1 1/2” Machine

 

 

 

Screws (7).

 

 

 

4. The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 240 volt ground

fault circuit interrupter (GFCI) installed in your home. This procedure must be performed by a qualified

electrician. A wiring diagram is found on the inside of the electronics pack as a reference. Under no

circumstances should the spa be wired by someone other than a qualified electrician. Before you

have the spa wired, make sure that it is in the position you want, and that it can be easily serviced, if needed.

5.After a qualified electrician has wired the spa to a 240 volt power source, refer to the inset drawing. Set the Filter (16) into the filter housing. Next, screw the Filter Cover (8) into the filter housing until it is fully seated.

Remove the two warning decals (not shown) from the spa shell. Using a damp cloth, wipe the spa shell clean. Before filling the spa, make sure that it is in the desired position and that there is room to easily service the spa. Once the spa is filled, it will have to be drained before it can be moved.

Using a garden hose or other clean water source, begin filling spa. Do not use soft water. The spa may be filled with cold water; however, if warm or hot water is used, the spa will be ready for use sooner. Fill the spa until the water is at the level shown at the right. Do not overfill the spa.

6.Pull down one of the straps on the Spa Cover (11) and hold the Buckle (30) against one of the WeatherWood™ panels on the spa. (Note: To posi- tion the Buckle correctly, have a second person hold the strap on the opposite side of the Spa Cover tight.) The Spa Cover must be tight. Do not place the Buckle over the grooves between the WeatherWood™ panels. Refer to the inset drawing. Remove the latch from the Buckle (30). Attach the Buckle to the WeatherWood™ panel with two #4 x 3/4” Screws (31).

Attach the other five Buckles (30) to the WeatherWood™ panels in the same way.

Remove the Spa Cover (11) from the spa.

5

 

8

 

 

16

 

Fill to Here

Filter

 

 

Filter

 

Housing

Housing

 

 

6

 

 

11

 

Strap

 

 

 

 

Latch

 

 

30

 

 

31

 

 

Strap

 

 

30

9

Page 9
Image 9
Image IMHS63100 electrician. A wiring diagram is found on the inside of the electronics pack as a reference. Under no