SFP Ports

or

One model offers two SFP (A and B) ports for 1+1 protection; a second model offers one SFP without protection.

ACT:

Glows green when the SFP port is the active receive line.

OFF when the SFP is not the receive line

Glows red+green when the SFP port is manually forced to

be the active receive line

LNK:

Glows green when there is a valid link

Glows red when a loss of optical signal occur, LOF, or with continuous optical bit errors

RAI:

Off when no remote defects are detected

Glows red+green when remote LOS or BER detected

MSA:

Off when no SFP is installed in the port

Glows green when no SFP alarms are detected

Glows red+green when SFP alarms or defects are detected at remote end

Glows red when SFP alarms or misconfigurations are detected locally, i.e., when the SFP is missing, or when SFP speed is not at 155Mbps

8

Page 12
Image 12
IMC Networks IE-IMCV-T1-MUX/4 operation manual SFP Ports, Act