Built-in Installation

This oven can be built into any standard space in cabinetry whose dimensions meet European standards.

No special precautions are needed for its installation, due to:

-Reinforced insulation which limits heat exchanges,

-Frontal ventilation requiring no air inlet.

Installation must be carried out by a qualified professional and meet all applicable safety standards. The guarantee for the appliance does not cover any damage caused by improper installation.

Proper installation is also required to ensure the users’ safety and a long useful life for the appliance.

Appliance meeting CE standards according to directives: DBT 73/23 CEE modified by directive 93/68/ CEE CEM 89/336/CEE

There are two ways to connect the oven during installation:

-By using an electrical plug,

-By using a connection panel.

In both cases, refer to the table above for the minimum diameters of the wires and the calibration of the protec- tive components according to the type of connection.

3GB10

585

Manual background 550 Manual background

560

545

588

595

23

If the appliance is connected using a connection panel, an omnipolar switchgear with a minimum distance be- tween contacts of 3 mm must be installed upstream from the connection of the appliance.

We recommend that you use a power cord that is long enough to allow the oven to be pulled out for maintenance operations. Use only cables of HAR - H 05 - RRF quality equipped with a plug that complies with the regulations of the country where the installation takes place. The plug must be accessible.

Before any maintenance or repair operation, includ- ing replacing the light bulb, you must first discon- nect the appliance.

To fix the oven in place, open the door and fasten the 2 screws (provided with the appliance) in the 2 correspond- ing holes.

Power connection

Before connecting the power, the meter must be checked to verify the conditions for the delivery of the available electrical energy — number of phases, voltage, maximum power necessary — which must be compatible with the Indesit appliance in question.

Indesit ovens can be adapted to the following electrical installations:

It is hazardous to operate an appliance that has not been properly earthed.

Important: After connecting the appliance to the flexible cable, tighten all the screws of the terminal plate.

Electrical connection

Voltage

Power

Fuse

Frequency

 

 

 

 

 

 

 

54 3 2 1 FR-BE-CH-DE-DK-ES-IL-GB-IT-NL-AT-GR-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RE-MA-LU-IE-FI-PT-NZ

2,99 kW

16 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SE-IS

1,5 mm

 

 

 

 

 

 

 

N

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

230 V 1+N 50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

FR-BE-NO

 

16 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,99 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230 V 2 50 Hz

1,5 mm

 

 

 

 

 

 

 

L2

 

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CY-MT-AU-NZ-KW

3,26 kW

16 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240 V 1+N 50 Hz

1,5 mm

 

 

 

 

 

 

 

N

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

GB10