Burner and nozzle characteristics

Table 1

 

 

 

 

 

Liquid Gas

 

 

 

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Diameter

Thermal Power

By-Pass

Nozzle

Flow*

 

Nozzle

 

Flow*

Nozzle

Flow*

 

(mm)

kW (p.c.s.*)

1/100

1/100

g/h

 

1/100

 

l/h

1/100

l/h

 

 

Nominal

 

Reduced

(mm)

(mm)

***

 

**

(mm)

 

 

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast

100

3.00

 

0.7

41

87

218

 

214

128

 

286

143

286

(Large)(R)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi Fast

75

1.90

 

0.4

30

70

138

 

136

104

 

181

118

181

(Medium)(S)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

51

1.00

 

0.4

30

52

73

 

71

76

 

95

80

95

(Small)(A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven

-

3.10

 

1.0

46

85

225

 

221

132

 

295

148

288

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grill

-

2.50

 

-

-

80

182

 

179

122

 

238

139

227

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

Nominal (mbar)

 

 

28-30

 

37

20

 

13

 

Minimum (mbar)

 

 

20

 

25

17

 

6,5

 

Pressures

 

 

 

 

 

Maximum (mbar)

 

 

35

 

45

25

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

 

Natural

P.C.S. = 37,78 MJ/m3

S S

A R

K1G21/R

K1G21S/R

7

Page 7
Image 7
Indesit manual Burner and nozzle characteristics, Liquid Gas Natural Gas, K1G21/R K1G21S/R