Indesit KD3G specifications Adapting the cooker to different types of gas

Models: KD3G

1 25
Download 25 pages 42.5 Kb
Page 6
Image 6
Adapting the cooker to different types of gas

rating of 45 amp. In this case the cable is not supplied.

Disposing of the plug:

Ensure that before disposing of the plug itself, you make the pins unusable so that it cannot be accidentally inserted into a socket. Instructions for connecting cable to an alternative plug:

￿the wires in the mains lead are coloured in accordance with the following code:

Green & Yellow

- Earth

Blue - Neutral

 

Brown - Live

If the colours of the wires in the mains lead do not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

Connect Green & Yellow wire to terminal marked “E”

or

 

 

 

 

 

or coloured Green or Green & Yellow.

 

 

 

 

 

 

 

 

 

 

 

 

Connect Brown wire to terminal marked “L” or coloured Red.

Connect Blue wire to terminal marked “N” or coloured Black.

If a 13 amp plug (BS 1363) is used it must be fitted with a 13 amp fuse. A 15 amp plug must be protected by a 15 amp fuse, either in the plug or adaptor or at the distribution board. If you are in any doubt about the electrical supply to your machine, consult a qualified electrician before use.

How to connect an alternative plug:

a)replace the hose holder mounted on the appliance

with that supplied in the bag of “cooker

GB

accessories”.

 

b )Replacing the burner nozzles on the hob:

remove the grids and slide the burners from their housings;

• unscrew the nozzles using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see table 1 “Burner and nozzle characteristics”).

replace all the components by repeating the steps in

reverse order.

c)Minimum regulation of the hob burners:

turn the tap to minimum;

remove the knob and

adjust the regulation screw, which is positioned in or next to the tap pin, until the flame is small but steady.

￿ in the case of liquid gas, the

regulation screw must be screwed in to the bottom.

check that the flame does not turn off when you turn the tap quickly from high to low.

d )Regulating the primary air of the burners:

The primary air of the burners requires no regulation.

GREEN &

YELLOW

BROWN

13 amp fuse

 

BLUE

CROSS-BAR

 

CORD GRIP

The wires in this mains lead are coloured in accordance with the following code:

B L U E “NEUTRAL” (“N”) B R O W N “LIVE” (“L”)

GREEN AND YELLOW “EARTH” (“E”)

Adapting to different types of gas

In order to adapt the oven to a different type of gas with respect to the gas for which it was manufactured (indicated on the label), follow these simple steps:

Disposing of the appliance

When disposing of the appliance please remove the plug by cutting the mains cable as close as possible to the plug body and dispose of it as described above.

Adapting the cooker to different types of gas

In order to adapt the cooker to a different type of gas with respect to the gas for which it was produced (indicated on the label attached to the lid), follow these steps:

a)Replacing the oven burner nozzle

• open the oven door fully

• pull out the sliding oven bottom

Z

V

V

5

Page 6
Image 6
Indesit KD3G specifications Adapting the cooker to different types of gas