Indesit KD3G11/G manual Electrical connection, 2 L

Models: KD3G11/G

1 24
Download 24 pages 62.66 Kb
Page 6
Image 6
Electrical connection

flame is small but steady.

N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom.

check that the flame does not turn off when you turn the tap quickly from high to low.

c)Regulating the primary air of the burners:

The primary air of the burners requires no regulation.

Important

On completion of the operation, replace the old rating sticker with one indicating the new type of gas used. This sticker is available from our Service Centres.

Note

Should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to “regulators for channelled gas”.

Electrical connection

WARNING – THIS APPLIANCE MUST BE EARTHED.

Fig. A

2 L

4 N

Fig. B

Electrical connection

Electric cookers come without a power supply cable. The cooker is designed to operate on an electricity supply which conforms to the electrical data shown on the Rating Plate.The cooker can be connected to the mains only after removing the back panel of the cooker itself with a screwdriver.

N.B.: the following installation procedure must be carried out by a qualified electrician. The electrical installation must comply with the IEE Regulations, Building & local By- Lays.

For the installation of the feeding cable carry out the following operations:

lUsing a screwdriver, prise on the side tabs of the terminal board cover (see fig. A);

lPull and open the junction blok lid

Important: the wires in the mains lead are coloured in accordance with the following code:

Green & Yellow Earth

Blue Neutral

Brown Live

As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

Green & Yellow wire to terminal marked “E” or

 

 

 

 

 

 

or coloured Green or Green &

 

 

 

 

 

 

Yellow.

 

 

 

 

 

 

Brown wire to terminal marked “L” or coloured Red.

 

Blue wire to terminal marked “N” or coloured Black (see fig. B).

lfix the feeding cable in the special cable stop and close the cover.

N.B.: the power supply cable must have these minimum requirements:

Type: H05RR-F

Section: 3x1.5 mm2

Ensure that the mains cable is routed away from any brackets affixed to the rear panel and is not trapped to the rear wall when pushing the cooker into position between cabinets.

6

Page 6
Image 6
Indesit KD3G11/G manual Electrical connection, 2 L