•Rotate to the left to increase the flame and rotate to
the right o lower the flame.
N.B.: in the case of liquide gas, the regulation screw must be screwed in the bottom.
Check that the flame does not turn off when you turn the tap quickly from hugh to low
A B
A
T
C
B
SB
Fig. A | Fig. B |
Attention:
On completion of the above operation, please replace the current technical data label with a new one containing details of the gas which the appliance has now been converted to. The new technical data label is contained in the nozzles Kit supplied with the cooker.
Note
Should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to “regulators for channelled gas”.
Table 1
| Regulating air "a" (mm) | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burner | Butane | Natural Gas |
|
|
|
|
|
|
|
|
|
|
|
| Propane | G 20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fast large |
|
|
|
|
|
|
|
|
|
|
|
|
|
(Front right) | 11 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Fast |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
(Rear left) | 13 | 0 |
|
|
|
|
|
|
|
|
|
|
|
Medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 0 |
|
| a | |||||||||
(Rear right) | 13 |
|
| ||||||||||
Medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
(Front left) | 13 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burner and nozzles characteristics
Table 2
|
|
|
|
|
| Liquid Gas |
|
| Natural Gas | |||
|
|
|
|
|
|
|
|
|
|
|
| |
Burner | Diameter | Thermal power | Nozzle |
| Flow* | Nozzle |
| Flow* | ||||
| (mm) | kW |
| 1/100 | 1/100 |
| 1/100 |
| ||||
|
|
| g/h |
| l/h | |||||||
|
| (p.c.s.*) | (mm) | (mm) |
| (mm) |
| |||||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Max |
| Min. |
|
| *** |
| ** |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
90 | 3.30 |
| 0.70 | 42 | 90 | 240 |
| 236 | 135 |
| 314 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
78 | 2.70 |
| 0.70 | 42 | 83 | 196 |
| 193 | 122 |
| 257 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
50 | 1.70 |
| 0.40 | 29 | 65 | 124 |
| 121 | 97 |
| 162 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
50 | 1.70 |
| 0.40 | 29 | 65 | 124 |
| 121 | 97 |
| 162 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
Supply | Nominal (mbar) |
| 37** |
|
|
| 20 | |||||
Minimum (mbar) |
| 25** |
|
| 20*** |
| 17 | |||||
pressures |
|
|
|
| ||||||||
Maximum (mbar) |
| 45** |
|
| 35*** |
| 25 | |||||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
*At 15°C and 1013
** | Propane | P.C.S. = 50,37 MJ/Kg |
*** | Butane | P.C.S. = 49,47 MJ/Kg |
| Natural | P.C.S. = 37,78 MJ/m3 |
5