InFocus IN5102, IN5104 Error Conditions, Limitations, Write Command Examples, Function, Default

Models: IN5102 IN5106 IN5104

1 51
Download 51 pages 48.46 Kb
Page 44
Image 44
Write Command Examples

Write Command Examples

Function

Command

Response

 

 

 

Brightness

(BRT140)

Sets the brightness to 140

 

 

 

Power

(PWR0)

Turns power off

 

 

 

Power

(PWR1)

Turns power on

 

 

 

Error Conditions

Not all commands are supported for all projectors. If an unsupported com- mand is issued, the command will be ignored. If a command is received that is not understood, a ‘?’ character will be returned indicating the command was not understood.

Limitations

The projector cannot respond to commands coming in at a high-rate. There- fore, a delay must occur between commands to ensure that the command gets properly executed. To assure the projector can process a command, wait 3 seconds before entering the next command.

The Step column refers to increasing or decreasing the menu bar position since the On-screen Display is not an exact match of values. For example, Step 2 changes the data by 2 through the CLI (Command Line Interface). The menu bar is up (or down) by 1.

 

Com-

 

 

 

St

Function

Min

Max

Default

e

mand

 

 

 

 

p

 

 

 

 

 

 

 

 

 

 

 

About (Source Info)

ABT at W

0

1

n/a

 

0: n/a

 

 

 

 

 

1: enable

 

 

 

 

 

 

 

 

 

 

 

Active Iris

IRI at RW

0

2

1

 

0: Off

 

 

 

 

 

1: Presentation

 

 

 

 

 

2: Film

 

 

 

 

 

 

 

 

 

 

 

Aspect Ratio

ARZ at RW

0

2

2

 

0: Native

 

 

 

 

 

1: 16:9

 

 

 

 

 

2: 4:3

 

 

 

 

 

 

 

 

 

 

 

Auto Image

AIM at W

0

1

n/a

 

0: n/a

 

 

 

 

 

1: enable

 

 

 

 

 

 

 

 

 

 

 

Auto Power

APO at RW

0

1

0

 

0: disable

 

 

 

 

 

1: enable

 

 

 

 

 

 

 

 

 

 

 

Auto Source

ASC at RW

0

1

1

 

0: disable

 

 

 

 

 

1: enable

 

 

 

 

 

 

 

 

 

 

 

Blank

BLK at RW

0

1

0

 

0: off

 

 

 

 

 

1: on

 

 

 

 

 

 

 

 

 

 

 

43

Page 44
Image 44