Maintenance

Maintenance

Cleaning the Lens

1Apply a non-abrasive camera lens cleaner to a soft, dry cloth.

• Avoid using an excessive amount of cleaner, and don’t apply the cleaner directly to the lens. Abrasive cleaners, solvents or other harsh chemicals might scratch the lens.

2Lightly wipe the cleaning cloth over the lens in a circular motion. If you don’t intend to use the projector immediately, replace the lens cap.

Replacing the Projection Lamp

 

 

The lamp hours used timer in the About menu counts the number of hours

 

Lamp hours used

the lamp has been in use. Twenty hours before the lamp life expires, the

 

 

 

message “Change lamp” appears on the screen at startup. If the maximum

 

 

lamp time is exceeded, the lamp will not light. In this case, after replacing

 

 

the lamp you must reset the lamp hours by simultaneously pressing both

 

 

Volume buttons on the keypad and holding them for 10 seconds.

turn off and unplug

wait 30 minutes

 

projector

 

NOTE: You can order new lamp housings from your dealer. See the Packing list for information. Use only a replacement lamp with the same type and rating as the original lamp.

1 Turn off the projector and unplug the power cord.

2Wait 30 minutes to allow the projector to cool thoroughly.

3 Turn the projector on its side so that the lamp door is facing you. Using a flat-blade screwdriver, gently pry the lamp door from the projector by

placing the screwdriver blade into the space between the top of the lamplamp door door and the projector.