![STEP](/images/new-backgrounds/65117/6511711x1.webp)
PROGRAMMING (continued)
PRESSDISPLAYREMARKS
STEP
6
PROG
SETTING
THE
RELAYS
| PROG |
|
|
|
| PROG |
|
|
|
| PROG |
|
|
|
| PROG |
|
|
|
|
|
| This section sets up the relay information. | |
| PROG |
|
|
|
|
|
| Press the ``PROG key to choose ``TOT (relay B assigned | |
|
| or | to total) or ``PREW (relay B assigned to prewarn). Press | |
|
|
| ``enter when the desired choice is displayed. | |
| ENTER |
|
|
|
|
| ## ## | This will only appear if ``TOT is selected. This is the dura: | |
|
| tion (.01 - 99.99 seconds) that relay ``B will remain ener: | ||
|
|
| gized. If 00.00 is selected, the relay will latch until reset. | |
| ENTER |
|
|
|
|
|
| PRE A = Preset A (batch amount). The set point at which | |
SETTING |
| followed by | output ``A will drop out after started. If the displayed value is | |
THE | PRE A | last PRE A | not the desired preset, press the key(s) under the digit to be | |
PRESETS | entered | changed. |
| |
|
|
| PRE B = Preset B |
|
|
|
| a) tot selected | The set point at which output ``B will en: |
| PROG |
|
| ergize. |
|
| b) PrEw selected | The number of counts before batch ends | |
|
|
| ||
|
|
|
| that output ``B will drop out. |
|
|
| If the displayed value is not the desired preset, press the | |
|
|
| key(s) under the digit to be changed. | |
|
| flashes | Key in the lock code (see programming step 4) by pressing | |
SETTING |
| the keys under the digits to be changed. Press the ``enter | ||
| followed by: | |||
| key to enter the displayed code. | |||
THE |
| |||
|
| |||
LOCK |
|
|
| |
LOCK |
|
|
| |
|
|
|
| |
STATUS |
|
| After the code is entered, the unit will display ``LOC (unit | |
|
|
| ||
|
| or | is locked) or ``UN LOC (unit is unlocked). This message will | |
|
|
| be displayed for approximately 3 seconds before the unit re: | |
| ENTER |
| turns to the run mode. |
PAGE6 OF 8 | 67161(X |