EXCESSIVE AIR PRESSURE STATIC SPARK
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

SObtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions.

WARNING EXCESSIVE AIR PRESSURE. Can cause person- al injury, pump damage or property damage.

SDo not exceed the maximum inlet air pressure as stated on the pump model plate.

SBe sure material hoses and other components are able to with- stand fluid pressures developed by this pump. Check all hoses for damage or wear. Be certain dispensing device is clean and in proper working condition.

WARNING STATIC SPARK. Can cause explosion resulting in severe injury or death. Ground pump and pumping system.

SSparks can ignite flammable material and vapors.

SThe pumping system and object being sprayed must be grounded when it is pumping, flushing, recirculating or spray- ing flammable materials such as paints, solvents, lacquers, etc. or used in a location where surrounding atmosphere is conducive to spontaneous combustion. Ground the dispens- ing valve or device, containers, hoses and any object to which material is being pumped.

SSecure pump, connections and all contact points to avoid vibration and generation of contact or static spark.

SConsult local building codes and electrical codes for specific grounding requirements.

SAfter grounding, periodically verify continuity of electrical path to ground. Test with an ohmmeter from each component (e.g., hoses, pump, clamps, container, spray gun, etc.) to ground to insure continuity. Ohmmeter should show 0.1 ohms or less.

SSubmerse the outlet hose end, dispensing valve or device in the material being dispensed if possible. (Avoid free streaming of material being dispensed.)

SUse hoses incorporating a static wire.

SUse proper ventilation.

SKeep inflammables away from heat, open flames and sparks.

SKeep containers closed when not in use.

WARNING Pump exhaust may contain contaminants. Can cause severe injury. Pipe exhaust away from work area and per- sonnel.

SIn the event of a diaphragm rupture, material can be forced out of the air exhaust muffler.

SPipe the exhaust to a safe remote location when pumping haz- ardous or inflammable materials.

SUse a grounded 3/8” minimum i.d. hose between the pump and the muffler.

WARNING HAZARDOUS PRESSURE. Can result in serious

WARNING EXPLOSION HAZARD. Models containing alumi- num wetted parts cannot be used with III.-Trichloroethane, Me- thylene Chloride or other Halogenated Hydrocarbon solvents which may react and explode.

SCheck pump motor section, fluid caps, manifolds and all wetted parts to assure compatibility before using with solvents of this type.

WARNING MISAPPLICATION HAZARD. Do not use models containing aluminum wetted parts with food products for hu- man consumption. Plated parts can contain trace amounts of lead.

CAUTION Verify the chemical compatibility of the pump wetted parts and the substance being pumped, flushed or re- circulated. Chemical compatibility may change with tempera- ture and concentration of the chemical(s) within the substances being pumped, flushed or circulated. For specific fluid compatibility, consult the chemical manufacturer.

CAUTION Maximum temperatures are based on mechani- cal stress only. Certain chemicals will significantly reduce maximum safe operating temperature. Consult the chemical manufacturer for chemical compatibility and temperature lim- its. Refer to PUMP DATA on page 1 of this manual.

CAUTION Be certain all operators of this equipment have been trained for safe working practices, understand it’s limita- tions, and wear safety goggles / equipment when required.

CAUTION Do not use the pump for the structural support of the piping system. Be certain the system components are properly supported to prevent stress on the pump parts.

SSuction and discharge connections should be flexible connec- tions (such as hose), not rigid piped, and should be compatible with the substance being pumped.

CAUTION Prevent unnecessary damage to the pump. Do not allow pump to operate when out of material for long periods of time.

SDisconnect air line from pump when system sits idle for long periods of time.

CAUTION Use only genuine ARO replacement parts to as- sure compatible pressure rating and longest service life.

NOTICE RE-TORQUE ALL FASTENERS BEFORE OPERA- TION. Creep of housing and gasket materials may cause fas- teners to loosen. Re-torque all fasteners to insure against fluid or air leakage

injury or property damage. Do not service or clean pump, hoses or dispensing valve while the system is pressurized.

SDisconnect air supply line and relieve pressure from the sys- tem by opening dispensing valve or device and / or carefully and slowly loosening and removing outlet hose or piping from pump.

WARNING HAZARDOUS MATERIALS. Can cause serious in- jury or property damage. Do not attempt to return a pump to the factory or service center that contains hazardous material. Safe handling practices must comply with local and national laws and safety code requirements.

WARNING

CAUTION

NOTICE

=Hazards or unsafe practices which could result in severe personal injury, death or substantial property damage.

=Hazards or unsafe practices which could result in minor personal injury, product or property damage.

=Important installation, operation or maintenance information.

Page 2 of 8

PD10X-X-X

Page 2
Image 2
Ingersoll-Rand PD10X-X-X, PE10X-X-X manual Operating and Safety Precautions, Sparks can ignite flammable material and vapors

PD10X-X-X, PE10X-X-X specifications

Ingersoll-Rand has long been a leader in the manufacturing of high-quality air compressors, and the PE10X-X-X and PD10X-X-X models represent some of their most innovative offerings. These models are designed to meet the demands of various industrial applications, delivering robust performance and exceptional reliability.

The PE10X-X-X series stands out with its unique combination of power and efficiency. It features a reliable and durable rotary screw design, which allows for continuous operation with minimal maintenance. The modular design of the PE10X-X-X ensures easy accessibility for servicing, reducing downtime and enhancing productivity. Additionally, this model incorporates advanced cooling systems that maintain optimal performance, even under the toughest working conditions.

On the other hand, the PD10X-X-X series is engineered with an emphasis on versatility and user-friendly operation. This model is equipped with an innovative variable speed drive technology, which allows users to adjust the compressor's output according to their specific air demands. This not only optimizes energy consumption but also contributes to significant cost savings over time. The PD10X-X-X also features a state-of-the-art control system that provides real-time monitoring and diagnostics, enabling operators to make informed decisions regarding performance and maintenance.

Both models boast integrated soundproofing technologies that ensure quiet operation, making them suitable for use in environments where noise levels should be minimized. They are also designed with environmentally friendly refrigerants, adhering to industry standards for sustainability.

Ingersoll-Rand prides itself on the reliability of its compressors, and both the PE10X-X-X and PD10X-X-X models are no exception. Engineered for durability, these compressors are fitted with high-quality components that ensure consistent performance over an extended lifespan. Additionally, they come equipped with advanced filtration systems that help maintain clean air distribution, thus protecting downstream equipment.

In summary, the Ingersoll-Rand PE10X-X-X and PD10X-X-X models exemplify cutting-edge technology and user-centric design. With features such as rotary screw design, variable speed drive technology, advanced control systems, and soundproofing, these compressors deliver optimal efficiency and reliability for demanding industrial applications. Whether you need a high-performance solution for continuous operation or a versatile unit that adapts to varying demands, these models offer outstanding capabilities to meet the needs of modern businesses.