MS-5 Wiring Diagram

P/N 14356A

ELECTRICAL SHOCK

Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off.

Installation must conform to local electrical codes.

All control centers and disposers must be carefully and permanently grounded.

A properly fused disconnect must be installed at the electrical supply source for the control center.

PROPERTY DAMAGE

Ensure that the control center voltage and phase match the disposer motor and electrical supply. Check nameplates on disposers and control centers for voltage and phase specification.

The disposer motor wiring connection is shown in the disposer terminal box.

208 - 230 V

1-phase

1/2 to 2 HP

-1 -2

A2

13NO

14NO

11

A2

 

5L3

6T3

 

 

 

3L2

4T2

 

 

A1

1L1

2T1

2

 

L1 L2 L3

-3 -4

WATER SOLENOID VALVE

7

1

 

 

L1 L2

INCOMING

POWER

SUPPLY

TO PANEL GROUND

DISPOSER

MOTOR

6

5

4

3

2

Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.

8

Page 8
Image 8
InSinkErator installation manual MS-5 Wiring Diagram, 208 230 Phase To 2 HP