Intel ATX Power Supply Design Guide

Version 0.9

8.2 International

The vendor must provide a complete CB certificate and test report to IEC 950, 2nd edition + A1, A2, A3, and A4. The CB report must include ALL CB member country national deviations. CB report must include evaluation to EN60 950, + A1, A2, A3, A4 and EMKO-TSE (74-SEC) 207/94.

All evaluations and certifications must be for reinforced insulation between primary and secondary circuits.

It is highly recommended that the CB report be issued by NEMKO.

8.3 Proscribed Materials

Cadmium should not be used in painting or plating.

No quaternary salt electrolytic capacitors shall be used.

Page 31