Intel 747116-011 manual Configuring the Server for LAN Access

Models: 747116-011

1 27
Download 27 pages 34.44 Kb
Page 12
Image 12

13. Enter the following in the Emergency Management Port (EMP) dialog box:

Option

Entry

Enter New Password:

Enter the EMP password, up to 16 characters.

Verify New Password:

Re-enter the EMP password.

ESC Sequence:

+++ (default)

Hangup String:

ATH (default)

Modem Init String:

ATE1Q0V1X4&D0S0=0 (default). May require change based on the installed

 

modem requirements.

System Phone Number:

The phone number to access the EMP port connect to port COM2.

Access Mode:

Always Active. [default is Preboot]

Restricted Mode:

Disable. [default is Enable]

Connection Mode:

Modem Connect(default) for modem connections to COM2. Serial Connect

 

for direct serial connections to COM2.

14.Click Save, then Close.

15.Exit from the Server SSU.

16.Quit the Server Board CD-ROM menu.

17.Remove the Software Kit CD from the CD-ROM reader.

18.Reboot server and select F2 to re-enter BIOS setup.

19.Select Server.

20.Toggle “LAN Redirection” to enable.

21.Press “ESC” and save changes before rebooting.

Configuring the Server for LAN Access

To take advantage of LAN access and BMC LAN-Alerts features, server settings must be configured using the server System Setup Utility (SSU). After the settings are initialized they can be changed using the Client System Setup Utility (CSSU).

If you are going to define a SNMP community, be sure to do it before installing ISC.

1.Insert the Software Kit CD into the CD-ROM reader.

2.Restart the server.

3.When the “F2 to enter setup” message appears, quickly press F2.

4.In Setup, use the arrow keys to select the Boot menu.

5.Use the arrow keys to select Boot Device Priority then press Enter.

6.Select ATAPI CDROM and use the + key to move the selection to the top of the list.

7.Press F10.

8.Select Yes to confirm saving of the current settings and press Enter. The server restarts and boots from the Software Kit CD.

9.When the Server Board CD-ROM menu appears, use the arrow keys to select the Utilities menu and press Enter.

10.Select “Run System Utility” under the “Utilities” menu. You will see SSU executables installed the first time and then the Server SSU launches.

11.In the Available Tasks list select Platform Event Manager and click OK.

12

Installation Guide for the Intel Server Control

Page 12
Image 12
Intel 747116-011 manual Configuring the Server for LAN Access