BIOS SETUP

PC Health Status

This section shows the parameters in determining the PC Health Status. These parameters include temperatures, fan speeds and voltages.

Phoenix - AwardBIOS CMOS Setup Utility

PC Health Status

CPU Warning Temperature

75°C/167°F

System Temp.

45°C/113°F

CPU Temp

52°C/125°F

CPU FAN Speed (FAN3)

5400 RPM

System FAN Speed (FAN1)

5463 RPM

System FAN Speed (FAN2)

5388 RPM

Vcore(V)

1.02 V

VGMCH(V)

1.32 V

+3.3V

3.32 V

+5V

4.94 V

+12V

12.03 V

VBAT

3.21 V

5VSB(V)

4.96 V

Shutdown Temperature

Disabled

CPU Fan Failure Warning

Disabled

Sys. Fan Failure Warning

Disabled

Aux. Fan Failure Warning

Disabled

ITEM HELP

Menu Level >

CPU Warning Temperature

This field allows the user to set the temperature so that when the temperature is reached, the system sounds a warning. This function can help prevent damage to the system that is caused by overheating.

Temperatures/Voltages

These fields are the parameters of the hardware monitoring function feature of the motherboard. The values are read-only values as monitored by the system and show the PC health status.

Shutdown Temperature

This field allows the user to set the temperature by which the system automatically shuts down once the threshold temperature is reached. This function can help prevent damage to the system that is caused by overheating.

CPU/System/Chassis Fan Failure Warning

When enabled, this field lets the system sounds an audible warning to the user that the CPU fan or chassis fan has malfunctioned.

AR-B1760 User’s Manual

53

Page 57
Image 57
Intel AR-B1760 user manual PC Health Status, CPU Warning Temperature, Temperatures/Voltages, Shutdown Temperature