Intel cc2300, cc3300 manual Installing ISC Server Instrumentation

Models: cc2300 cc3300

1 20
Download 20 pages 18.55 Kb
Page 15
Image 15

Intel Server Control Installation Guide

NOTE

If you uninstall ucd-snmp, you must also remove all related snmp and DMI packages. When you remove these packages, remove them in an order that eliminates dependency error messages. For example, if a dependency error message appears, remove the package mentioned in the error message.

Continue removing the dependent packages in this manner until the error messages stop.

4. Install the DMI service provider package located in the \Software\Linux\dmisnmp directory on the HP Server cc3300 & cc2300 User Information, Diagnostics & Utilities Resource CD by using the rpm command. For example, the following command installs a version of the DMI service provider package:

rpm –i dmisp-1.0-6.i386.rpm

5.Locate and install the ucd-snmp RPM, ucd-snmp-utils RPM, and dmi2snmp RPM packages. These packages are also located in the \Software\Linux\dmisnmp directory on the HP Server cc3300 & cc2300 User Information, Diagnostics & Utilities Resource CD . Use the rpm command to install each package. For example, the following three commands install versions of these three packages (Note that these names may not be the same for Linux 7.1):

rpm –i ucd-snmp-4.1.1-15smux.i386.rpm

rpm –i ucd-snmp-utils-4.1.1-15smux.i386.rpm rpm –i dmi2snmp-1.0-15.i386.rpm

6. Reboot the Linux server after you have installed all the packages.

Installing ISC Server Instrumentation

1.Insert the HP Server cc3300 & cc2300 User Information, Diagnostics & Utilities Resource CD into the Linux server CD ROM drive.

2.Mount the CD using either of the following methods.

Enter the mount command as follows: mount /mnt/cdrom

Use the Disk Management utility. To invoke this utility click the Start button, select System, and then select the Disk Management menu option.

2. List the contents of the HP Server cc3300 & cc2300 User Information, Diagnostics & Utilities Resource CD and make sure the ISC install packages and scripts are on the CD. You can locate these packages in the /Software/Linux directory. Use the following commands to move to that directory and list the files:

cd /mnt/cdrom/Software/Linux ls

You should see filenames similar to the following:

ipmidrvr-2.2.14.6.1.1smp-1.i386.rpm ipmidrvr-2.4.2.2smp-1.i386.rpm isc-3.5-1.i386.rpm

installme