28 Intel® NetStructure™ MPCHC5525 System Master Processor Board IPMI Reference Dri ver User’s Guide
Supported IPMI Commands and B MC /PM Addresses

4.3.4.1 Request Data

4.3.4.2 Response Data

4.3.5 SetShadowRepositoryEnable

This command is used to enab le or disable the access to the shadow repository of an IPM I
controller in BMC stand-by mode.
Note: This command can only be used if IPMI controller is in BMC stand-by mode. If the IPMI
controller is not in BMC stand-by mode, “invalid command” is returned.

4.3.5.1 Request Data

4.3.5.2 Response Data

4.4 BMC and PM Addresses
To be able to send messages to other IPMI controllers (PMs) with your system management
software, you need the IPMI controller’s I2C address.
If the IPMI con troller acts as BM C, the I2C address is 2016.
If the IPMI controller is set to PM, it depends on the geographical address of the board in the
system. Refer to the system’s backplane desc ription to find the geographical addresses or use the
Force-specific IPMI command GetGeographicalAddress. The mapping of geographical and I2C
Byte Data Field
--
Byte Data Field
1 Completion Code
2 R ecord count LSB
3 Record count MSB
4 CRC16 LSB
5 CRC16 MSB
Byte Data Field
1Access
0: Disabled
1: Enabled
Byte Data Field
1 Completion Code