26 Intel® NetStructure™ MPCHC5525 System Master Processor Board IPMI Reference Dri ver User’s Guide
Supported IPMI Commands and B MC /PM Addresses
4.3 Force-Specific Commands
The Force Computers IPMI firmware supports several commands that are not defined in the IPMI
specification but are introduced by Force Computers. For more info rmation regarding Force-
specific OEM IPMI implementations , see the Intelligent Board Management Unit Reference Guide
(PN217328), available by contacting Force Computers.

4.3.1 BMC/PMChangeRole

This command is used to set the operation mode of the IPMI controller (BMC, PM or BMC stand-
by). In BMC stand-by mode, a mode provided by Force Computers, the IPMI controller is PM but
can manipulate the system event log (SEL) and sensor data reposito ries (SDR) like a BMC.

4.3.1.1 Request Data

4.3.1.2 Response Data

Get ICMB Connector Info Bridge 0A16
Prepare for Discovery Bridge 1016
Get Addresses B ridge 1116
Set Discovered Bridge 1216
Bridge Request Bridge 2016
Bridge Message Bridge 2116
Get Bridge Event Count Bridge 3016
Set Event Destination Bridge 3116
Set Event Reception State Bridge 3216
Send ICMB Event Message Bridge 3316
Get Event Destination Bridge 3416
Get Event Reception State Bridge 3516
Table 8. Implemented Optional ICMB Bridge Commands (Sheet 2 of 2)
Command Net Fn CMD
Byte Data Field
1
Role
0: BMC
1: BMC stand-by
2: PM
Byte Data Field
1 Completion Code