24 Intel® NetStructure™ MPCHC5525 System Master Processor Board IPMI Reference Dri ver User’s Guide
Supported IPMI Commands and B MC /PM Addresses
4.2.3 SEL Commands
All commands in this category define d as mandatory by t he IP MI specifi cati on a re im plemente d. In
addition, the following optional commands are available.
Note: SEL commands can only be used in BMC mode.
4.2.4 SDR Commands
All commands in this category define d as mandatory by t he IP MI specifi cati on a re im plemente d. In
addition, the following optional commands are available.
All commands can be used in every operation mode.
4.2.5 FRU Inventory Device Commands
All commands in this category defined as mandatory by the IPMI Speci f ication are implemented.
The commands can be used in every operation mode.
The FRU information returned by the IPMI command “Read FRU Inventory Data” is compatible
with the Platform Management FRU information Storage Definition v1.0.
The size of the complete FRU record consisting of:
Internal Use Area
Board Info Area
Product Info Area
Multi Record Area
is limited to 1024 bytes.
Table 5. Optional SEL Device Commands
Command NetFn CMD
Get SEL Allocation Info Storage 4116
Reserve SEL Storage 4216
Add SEL Entry Storage 4416
Partial Add SEL Entry Storage 4516
Delete SEL Entry Storag e 4616
Table 6. Optional SDR Device Commands
Command NetFn CMD
Get SDR Allocation Info Storage 2016
Add SDR Storage 2416
Partial Add SDR Storage 2516
Delete SDR Storage 2616
Get SDR Repository Time Storage 2816
Set SDR Repository Time Storage 2916