Online Capacity Expansion and RAID Level Migration Rules

Migration must occur to the same or larger capacity configuration.

Migration cannot occur if there is more than one virtual disk in a logical array.

Migration and OCE cannot be done on Spanned Arrays (RAID 10, 50, 60).

Migrations supported are : RAID 1 to RAID 0, RAID 5 to RAID 0, RAID 6 to RAID 0.

With OCE migrations supported are RAID 0 to RAID 1, RAID 0 to RAID 5, RAID 1 to RAID 5.

Beep Codes

Short beep, 1 second on, 1 second off. Array is degraded but no data lost.

Long beep, 3 seconds on, 1 second off. Array has failed. Data has been lost.

Short beep, 1 second on, 3 seconds off. Using hot spare in rebuild. Alarm will continue during rebuild with a different sound at completion.

To disable the alarm, choose Disable Alarm. To enable alarm, choose Enable Alarm.

To disable alarm only until the next event or until next power cycle, choose Silence Alarm.

5

Intel® RAID Controller SRCSATAWB Hardware User’s Guide

Page 10
Image 10
Intel SRCSATAWB manual Online Capacity Expansion and RAID Level Migration Rules, Beep Codes