Array Performance Features

Host data transfer rate

2.5 Gigabit/s per PCI Express* lane

 

 

Drive data transfer rate

3 Gigabit/s per lane

 

 

Maximum scatter / gather

26 elements

 

 

Maximum size of I/O requests

6.4 Mbytes in 64 Kbyte stripes

 

 

Max queue tags per drive

As many as the drive can accept

 

 

Stripe sizes

8, 16, 32, 64, 128, 256, 512 or 1024 KB

 

 

Max concurrent commands

255

 

 

Support for multiple initiators

Yes

 

 

Performance

Native command queuing

 

 

Flexibility

Drive migration, RAID level migration, Drive Roaming, Online

 

Capacity Expansion - without reboot

 

 

Background services

Rebuild, Consistency Check, Migration, OCE, and Patrol Read

 

 

Cache options

Write-back or Write-through Read Ahead, Adaptive Read

 

Ahead, NonRead Ahead, Cache I/O or Direct I/O

 

 

Fault Tolerance

Self Monitoring Analysis and

Detects up to 70% of predictable disk drive failures and

Reporting Technology (SMART)

monitors the internal performance of all motors, heads,

support

and drive electronics.

 

 

Optional Battery Backup

Intel® RAID Smart Battery AXXRSBBU4 cache backup.

 

Up to 72 hours of data retention. “Gas Gauge".

 

 

Drive Replacement

Auto detection of failure, hot plug, hot swap.

 

 

Drive Rebuild Using Hot Spares

Automatic at fail: Dedicated per Array; Global for any

 

array; Auto-resume of initialization or rebuild on reboot

 

 

Error Checking and Indication

Parity generation and checking, automatic consistency

 

checking; patrol reads; activity and fault LEDs, alarm;

 

multiple retries; logs in NVRAM, event log, CIM, Smart,

 

Intel® RAID Web Console 2

Intel® RAID Controller SRCSATAWB Hardware User’s Guide

12

Page 17
Image 17
Intel SRCSATAWB manual Array Performance Features, Fault Tolerance