NOTE: These recommendations will provide optimal protection against EMI and RFI. The actual cable type,
wire gauge, shield type and filtering devices used are dependent on the customer’s application and system.
IMS Driver Supply Cable AWG Table
1 Ampere (Peak)
Length (Feet) | 10 | 25 | 50* | 75* | 100* |
Minimum AWG | 20 | 20 | 18 | 18 | 16 |
|
|
|
|
|
|
2 Amperes (Peak) |
|
| |||
Length (Feet) | 10 | 25 | 50* | 75* | 100* |
Minimum AWG | 20 | 18 | 16 | 14 | 14 |
|
|
|
|
|
|
3 Amperes (Peak) |
|
| |||
Length (Feet) | 10 | 25 | 50* | 75* | 100* |
Minimum AWG | 18 | 16 | 14 | 12 | 12 |
|
|
|
|
|
|
4 Amperes (Peak) |
|
| |||
Length (Feet) | 10 | 25 | 50* | 75* | 100* |
Minimum AWG | 18 | 16 | 14 | 12 | 12 |
*Use the alternative methods illustrated in Examples A and B when the cable length is ≥ 50 feet. Also, use the same current rating when the alternate AC power is used.
Driver Supply Cable Wire Size
NOTE: Always use Shielded/Twisted Pairs for the IMS Driver DC Supply Cable, the AC Supply Cable and the IMS Driver to Motor Cable.
23