IMS Driver to Motor Cable AWG Table

IMS Driver to Motor Cable AWG Table

1 Ampere (Peak)

 

 

 

5 Amperes (Peak)

 

 

Length (Feet)

10

25

50*

75*

100*

 

Length (Feet)

10

25

50*

75*

100*

Minimum AWG

20

20

18

18

16

 

Minimum AWG

16

16

14

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Amperes (Peak)

 

 

 

6 Amperes (Peak)

 

 

Length (Feet)

10

25

50*

75*

100*

 

Length (Feet)

10

25

50*

75*

100*

Minimum AWG

20

18

16

14

14

 

Minimum AWG

14

14

14

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Amperes (Peak)

 

 

 

7 Amperes (Peak)

 

 

Length (Feet)

10

25

50*

75*

100*

 

Length (Feet)

10

25

50*

75*

100*

Minimum AWG

18

16

14

12

12

 

Minimum AWG

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Amperes (Peak)

 

 

 

* Use the alternate method illustrated in Example B

Length (Feet)

10

25

50*

75*

100*

 

 

when cable length is 50 feet.

 

 

 

Minimum AWG

18

16

14

12

12

 

 

 

 

 

 

 

 

 

 

 

Driver to Motor Supply Cable Wire Size

NOTE: These recommendations will provide optimal protection against EMI and RFI. The actual cable type,

wire gauge, shield type and filtering devices used are dependent on the customer’s application and system.

NOTE: Always use Shielded/Twisted Pairs for the IMS Driver DC Supply Cable, the AC Supply Cable and the IMS Driver to Motor Cable.