SPECIFICATIONS of the JPX-160

SPECIFICATIONS of the JPX-160

PERFORMANCE/CAPABILITIES

OPERATING CAPACITY (RACKS/HOUR)

RACKS PER HOUR

DISHES PER HOUR

GLASSES PER HOUR

OPERATING CYCLE (SECONDS) WASH TIME

JRINSE TIME

PTOTAL CYCLE TIME

X

1TANK CAPACITY (GALLONS)

ELECTRICAL REQUIREMENTS

WASH PUMP MOTOR HORSEPOWER

1/2

24NOTE: Typical Electrical Circuit is based upon (1) 125% of the

192full amperage load of the machine and (2) typical fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local

600codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes. These numbers are

107

provided in this manual simply for reference and may change

without notice at any given time.

 

 

14

 

 

 

 

 

 

 

 

121

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

 

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

 

208

1

60

2.7 KW@208V

24

30 AMP

 

230

1

60

3.3 KW@230V

26

35 AMP

6

0

WASH TANK (MINIMUM)

RINSE TANK

3.4

1.4WATER REQUIREMENTS

TEMPERATURES

WASH---°F (MINIMUM)

RINSE---°F

 

INLET TEMPERATURE

140°F

 

GALLONS PER RACK

.59

150

GALLONS PER HOUR

14.2

180

WATER LINE SIZE I.P.S. (Minimum)

1/2”

 

DRAIN LINE SIZE I.D.

1”

 

FLOW PRESSURE P.S.I.

20 A5

 

FRAME DIMENSIONS

 

 

WIDTH

19”

 

DEPTH

20”

 

HEIGHT

29 5/8”

 

MAXIMUM INSIDE CLEARANCE

14”

NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.

This equipment is not recommend for use with deionized water or other aggressive fluids. Use of deionized water or other aggressive fluids will result in corrosion and failure of materials and components. Use of deionized water or other aggressive fluids will void the manufacturer's warranty.