SPECIFICATIONS of the JPX-160
PERFORMANCE/CAPABILITIES
OPERATING CAPACITY (RACKS/HOUR)
RACKS PER HOUR
DISHES PER HOUR
GLASSES PER HOUR
OPERATING CYCLE (SECONDS) WASH TIME
JRINSE TIME
PTOTAL CYCLE TIME
X
1TANK CAPACITY (GALLONS)
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER | 1/2 |
24NOTE: Typical Electrical Circuit is based upon (1) 125% of the
192full amperage load of the machine and (2) typical
600codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes. These numbers are
107 | provided in this manual simply for reference and may change | |||||
without notice at any given time. |
|
| ||||
14 |
|
| ||||
|
|
|
|
|
| |
121 |
|
|
| RINSE |
| TYPICAL |
|
|
| HEATER | TOTAL | ELECTRICAL | |
| VOLTS | PH | HZ | RATINGS | AMPS | CIRCUIT |
| 208 | 1 | 60 | 2.7 KW@208V | 24 | 30 AMP |
| 230 | 1 | 60 | 3.3 KW@230V | 26 | 35 AMP |
6
0
WASH TANK (MINIMUM)
RINSE TANK
3.4 |
1.4WATER REQUIREMENTS
TEMPERATURES
| INLET TEMPERATURE | 140°F |
| GALLONS PER RACK | .59 |
150 | GALLONS PER HOUR | 14.2 |
180 | WATER LINE SIZE I.P.S. (Minimum) | 1/2” |
| DRAIN LINE SIZE I.D. | 1” |
| FLOW PRESSURE P.S.I. | 20 A5 |
| FRAME DIMENSIONS |
|
| WIDTH | 19” |
| DEPTH | 20” |
| HEIGHT | 29 5/8” |
| MAXIMUM INSIDE CLEARANCE | 14” |
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.
This equipment is not recommend for use with deionized water or other aggressive fluids. Use of deionized water or other aggressive fluids will result in corrosion and failure of materials and components. Use of deionized water or other aggressive fluids will void the manufacturer's warranty.
21