CHEMICAL TIMER ADJUSTMENTS CONTINUED
Use the chart below to determine the initial time values for INITIAL RINSE, CYCLE RINSE, INITIAL SOAP, and CYCLE SOAP based on the desired concentration of the chemical being used. Check the concentration of the chemicals after running a few cycles and read- just as necessary.
JPX-160
Chemical Ratio | Chemical | Chemical | Initial | Cycle | Initial | Cycle |
(parts water to | Concentration | Concentration | Rinse | Rinse | Detergent | Detergent |
one part chemical) (percent in water) | (ounces per | (sec) | (sec) | (sec) | (sec) | |
|
| 10 gallons water) |
|
|
|
|
5000 | 0.02% | 0.3 | 7 | 4 | 3 | 1 |
3000 | 0.03% | 0.4 | 12 | 7 | 5 | 1 |
2500 | 0.04% | 0.5 | 14 | 8 | 6 | 2 |
2000 | 0.05% | 0.6 | 18 | 10 | 8 | 2 |
1500 | 0.07% | 0.9 | 24 | 14 | 10 | 3 |
1000 | 0.10% | 1.3 | 36 | 20 | 16 | 4 |
800 | 0.13% | 1.6 | 45 | 26 | 20 | 5 |
600 | 0.17% | 2.1 | 60 | 34 | 26 | 6 |
400 | 0.25% | 3.2 | 90 | 51 | 39 | 9 |
300 | 0.33% | 4.3 | 119 | 68 | 52 | 13 |
250 | 0.40% | 5.1 | 143 | 82 | 63 | 15 |
200 | 0.50% | 6.4 | 179 | 102 | 78 | 19 |
JPX-200
Chemical Ratio | Chemical | Chemical | Initial | Cycle | Initial | Cycle |
(parts water to | Concentration | Concentration | Rinse | Rinse | Detergent | Detergent |
one part chemical) (percent in water) | (ounces per | (sec) | (sec) | (sec) | (sec) | |
|
| 10 gallons water) |
|
|
|
|
5000 | 0.02% | 0.3 | 11 | 5 | 8 | 1 |
3000 | 0.03% | 0.4 | 18 | 9 | 14 | 2 |
2500 | 0.04% | 0.5 | 22 | 10 | 16 | 2 |
2000 | 0.05% | 0.6 | 27 | 13 | 21 | 2 |
1500 | 0.07% | 0.9 | 36 | 17 | 27 | 3 |
1000 | 0.10% | 1.3 | 54 | 26 | 41 | 5 |
800 | 0.13% | 1.6 | 67 | 32 | 52 | 6 |
600 | 0.17% | 2.1 | 90 | 43 | 69 | 8 |
400 | 0.25% | 3.2 | 134 | 64 | 103 | 12 |
300 | 0.33% | 4.3 | 179 | 85 | 137 | 16 |
250 | 0.40% | 5.1 | 215 | 102 | 165 | 19 |
200 | 0.50% | 6.4 | 269 | 128 | 206 | 24 |
I
N S T R U C T I O N S
4