Use the chart below to determine the initial time values for INITIAL RINSE, CYCLE RINSE, INITIAL SOAP, and CYCLE SOAP based on the desired concentration of the chemical being used. Check the concentration of the chemicals after running a few cycles and read- just as necessary.

JPX-160

Chemical Ratio

Chemical

Chemical

Initial

Cycle

Initial

Cycle

(parts water to

Concentration

Concentration

Rinse

Rinse

Detergent

Detergent

one part chemical) (percent in water)

(ounces per

(sec)

(sec)

(sec)

(sec)

 

 

10 gallons water)

 

 

 

 

5000

0.02%

0.3

7

4

3

1

3000

0.03%

0.4

12

7

5

1

2500

0.04%

0.5

14

8

6

2

2000

0.05%

0.6

18

10

8

2

1500

0.07%

0.9

24

14

10

3

1000

0.10%

1.3

36

20

16

4

800

0.13%

1.6

45

26

20

5

600

0.17%

2.1

60

34

26

6

400

0.25%

3.2

90

51

39

9

300

0.33%

4.3

119

68

52

13

250

0.40%

5.1

143

82

63

15

200

0.50%

6.4

179

102

78

19

JPX-200

Chemical Ratio

Chemical

Chemical

Initial

Cycle

Initial

Cycle

(parts water to

Concentration

Concentration

Rinse

Rinse

Detergent

Detergent

one part chemical) (percent in water)

(ounces per

(sec)

(sec)

(sec)

(sec)

 

 

10 gallons water)

 

 

 

 

5000

0.02%

0.3

11

5

8

1

3000

0.03%

0.4

18

9

14

2

2500

0.04%

0.5

22

10

16

2

2000

0.05%

0.6

27

13

21

2

1500

0.07%

0.9

36

17

27

3

1000

0.10%

1.3

54

26

41

5

800

0.13%

1.6

67

32

52

6

600

0.17%

2.1

90

43

69

8

400

0.25%

3.2

134

64

103

12

300

0.33%

4.3

179

85

137

16

250

0.40%

5.1

215

102

165

19

200

0.50%

6.4

269

128

206

24