WHIRL WIZARD 240 VOLT - 50/60 HZ - SINGLE PHASE

SECTION 5: ELECTRICAL SCHEMATICS

WHIRL WIZARD 240 VOLT - 50/60 HZ - SINGLE PHASE

9905-002-33-80

SEQUENCE OF OPERATION

1.After the sink is filled with water, power switch (S1) is placed in the “ON” position.

2.Motor contactor (R1) is energized.

3.Pump motor (M1) starts.

4.Heater element (H1) is energized.

5.Power light (E1) is energized.

NOTE: THE HEATER ELEMENT CONTAINS AN INTERNALLY-MOUNTED THERMOSTAT TO REGULATE THE TEMPERA- TURE OF THE ELEMENT.

Whirl Wizard Technical Manual 7610-011-70-65

Issued: 08-20-2007 Revised: N/A