CV-M77

7 Configuring the camera using the serial interface.

7.1Mode Setting using ASCII commands via the RS-232C port.

The configuration of the CV-M77 camera can be done via the RS-232C port. The camera is to be set up via an ASCII terminal or from a PC running terminal emulator software.

Below is the description of the ASCII based short command protocol.

The RS-232C serial interface specification for CV-M77 is:

7.2

Communication setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud Rate

 

9600bps

 

 

 

 

 

 

Data Length

 

8bit

 

 

 

 

 

 

 

Stop Bit

 

 

1bit

 

 

 

 

 

 

 

Parity

 

 

Non

 

 

 

 

 

 

 

Xon/Xoff Control

 

Non

 

 

 

 

7.3

Command Protocol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command Name

 

Format

 

 

 

Parameter

Remarks

A -

General settings and

useful commands.

 

 

 

 

 

 

 

 

 

 

 

 

0=Echo off

 

1

Echo back

EB=[Param.]<CR><LF>

1=Echo on

 

 

 

 

 

 

 

 

Set to 'off' when power is on.

 

2

Firmware program

VN?<CR><LF>

 

 

 

 

Response is 3 letter

 

version request

 

 

 

 

 

 

(ex) 100

B -

Timing and shutter related commands.

 

 

 

 

 

1

Shutter mode

SM=[Param.]<CR><LF>

0=Normal

 

SM?<CR><LF>

 

1=Programmable exposure

 

 

 

 

 

 

 

 

 

 

 

SH=[Param.]<CR><LF>

0=OFF(1/25), 1=1/50, 2=1/125,

Available when SM=0 and

2

Shutter speed

3=1/250, 4=1/500, 5=1/750,

SH?<CR><LF>

 

6=1/1000, 7=1/1500, 8=1/2000,

TR=0 or 1or 3.

 

 

 

 

 

 

 

 

 

 

 

 

9=1/3000, 10=1/4000, 11=1/10000

 

 

 

 

 

 

 

 

3-791

 

 

 

 

 

 

 

 

 

(1/10000s - 1/25s in 1HD

 

 

Programmable

PE=[Param.]<CR><LF>

increments)

Available when SM=1 and

3

3= 1.5H(0.076ms)

 

exposure

PE?<CR><LF>

 

TR=0 or 1 or 3.

 

 

 

 

 

 

 

4=

2.5H(0.127ms)

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

791=789.5H(40.107ms)

 

 

 

 

 

 

 

 

0=Normal

 

 

 

 

 

TR=[Param.]<CR><LF>

1=Edge pre-select

 

4

Trigger mode

2=Pulse width control

 

TR?<CR><LF>

 

3=Frame delay readout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4=Long time shutter

 

 

 

 

 

 

 

 

5=PWC delay readout

 

5

Wen polarity

WP=[Param.]<CR><LF>

0=Active_L, 1=Active_H

 

WP?<CR><LF>

 

 

 

 

 

 

 

 

 

 

 

6

G on SYNC

SY=[Param.]<CR><LF>

0=OFF, 1=ON

 

SY?<CR><LF>

 

 

 

 

 

 

 

 

 

 

 

7

EEN polarity

EP=[Param.]<CR><LF>

0=Active_L, 1=Active_H

 

EP?<CR><LF>

 

 

 

 

 

 

 

 

 

 

 

8

WEN/Sync switch

WS=[Param.]<CR><LF>

0=WEN, 1=Sync

 

WS?<CR><LF>

 

 

 

 

 

 

 

 

 

 

 

- 16 -

Page 16
Image 16