These products are in compliance with the EMC Directive 89/336/EEC and Article 10 (1) of the directive. In compliance with Technical Regulations EN50081-1 and EN50082-1. For a copy of the model-specific CE Declaration of Conformity, contact JBL at the address listed at the end of this manual.

Maintenance

No maintenance is required when installed in accordance with installation and wiring guidelines described in this manual.

Control 24CT Micro

Transformer Taps: 70V: 9W, 4W, 2W, 1W, 0.5W 100V; 9W, 4W, 2W, 1W

Control 24CT MicroPlus

Transformer Taps: 70V: 25W, 12W, 6W 100V; 25W, 12W

Control 24C Micro

Power Capacity: 15W Continuous Pink Noise (UL shaped pink noise as defined by a 6dB Crest Factor)

30W Continuous Program POwer (Defined as 3dB above Pink Noise Power)

Continuous-Tone Test Rating: 5.3V RMS (Pure sine wave signal swept from 800 Hz to 2400 Hz over ten seconds)

NOTE

When using a distributed line system, the distribution amplifier is incapable of producing an output voltage higher than its rating (70.7 V or 100 V depending on geographic region). This is a peak voltage rating. As such, loudpseakers utilizing distribution transformers are not rated for voltage inputs in excess of those amplifier specifications.