DOWNDRAFT COOKTOP DUCTING ARRANGEMENTS

The diagrams below show typical duct arrangements for downdraft cooktops. JX3™ downdraft cooktops also offer a duct-free installation option. For more details, refer to page 3.

DUCTING CONFIGURATIONS

Roof jack

314" x 10"

DUCTING CONFIGURATIONS (8.3 cm x 25.4 cm) duct –

54' (16.5 m) max.

Roof jack Transition elbow

REAR DUCTING IN WALL TO ROOF

REAR DUCTING THROUGH WALL TO OUTSIDE

Transition elbow

314" x 10"

 

 

(8.3 cm x 25.4 cm) duct

SIDE DUCTING IN TOE KICK TO OUTSIDE

DUCTING REQUIREMENTS

cooktop

duct length

duct size

 

 

 

 

10' (3.0 m) or less*

5" (12.7 cm)

 

diameter*

 

 

 

 

 

Gas

 

6" (15.2 cm)

Between 10' (3.0 m)

diameter

 

 

and 60' (18.3 m)

314" x 10"

 

 

(8.3 cm x 25.4 cm)

 

 

 

 

10' (3.0 m) or less**

5" (12.7 cm)

 

diameter**

 

 

 

 

 

Electric

 

6" (15.2 cm)

Between 10' (3.0 m)

diameter

 

 

and 60' (18.3 m)

314" x 10"

 

 

(8.3 cm x 25.4 cm)

 

 

 

*Gas cooktops must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.

**May be used to vent straight out the back of the cooktop and directly through the wall.

CALCULATING MAXIMUM DUCTING LENGTH

Maximum ducting length is 60' (18.3 m).

Each 90° elbow equals 5' (1.5 m) duct.

Use no more than three 90° elbows.

Flexible metal vent is not recommended.

Do not install two elbows together.

NOTES:

For ducting runs up to 30' (9.1 m), install cooktop as shipped.

For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the restricter ring on the blower inlet housing.

For altitudes above 4500' (1272.0 m), reduce recommended vent run by 20% for best performance.

6" (15.2 cm) diameter duct –

5112' (15.7 m) max.

5" (12.7 cm ) to 6" (15.2 cm)

diameter transition

6" (15.2 cm)

diameter elbow6" (15.2 cm) diameter wall cap
THROUGH FLOOR between joists TO OUTSIDE

Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing

JRC120014A 07/2012

any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.

Page 4
Image 4
Jenn-Air JED4536W Downdraft Cooktop Ducting Arrangements, Ducting Configurations, Ducting Requirements, Transition elbow