After the above operation, the burner will produce a stable, steady blue flame of minimum size. The setting should be checked by turning knob from high to low several times without extinguishing the flame.
The above operation will automatically provide the proper flame size at medium setting.
After Conversion Steps A, B and C have been completed, check the appearance of each burner flame at the Hi and Lo settings against figure 14. If the flames appear too large or too small, review each step to make sure it was completed correctly.
FLAME APPEARANCE AT HI AND LO
4.For Step 5: Locate the brass natural gas orifice spuds that were originally installed in this appliance before its conversion for use with LP gas. Observe the number on each of the spuds and note the correct burner location for each spud as shown in figures 15 and 16.
Installation Of Natural Gas Orifice Spuds
5 BURNER MODEL (36 WIDE)
FIGURE 14
To Convert Appliance For Use With Natural Gas
Electrical power and gas must be turned off prior to conversion.
If this appliance has been converted for use with LP gas, each of the following modifications must be performed to convert the unit back to natural gas.
A. REPLACE ALL ORIFICE SPUDS.
1.Perform Steps 1 and 2 on page 8.
2.Remove chokes from the left front, center and right rear orifice holder (see figures 10 and 11). As required a simple paper clip can be used to remove the left front and right rear choke.
3.Perform Step 3 on page 8.
FIGURE 15
FIGURE 16
10