Jenn-Air JGD8130 InstructionsToInstaller, AirShutterAdjustment, ShuttersSeeIllustrationsA & B

Models: JGD8130 JGD8345

1 8
Download 8 pages 46.45 Kb
Page 3
Image 3
InstructionsToInstaller

InstructionsToInstaller

1.Chamfer all exposed edges of decorative laminate to prevent damage from chipping,

2. Radius corners of outout and file to insure smooth edges and prevent corner cracking. Recommend

1/4" or 3/8" diameter drill in each corner,

3. Rough edges, inside comers which have not been rounded and forced fit can contribute to cracking of the counter top laminate.

4, Countertopmust be supportedw(thin 3" of cutout.

Minimum horizontal clearance between the edge of the

appliance and combustible construction extending from the cooking surface to 18" (45.7 cm)above the cooking surface is:

15/16" (2.38 cm) at rear

8" at sides

This is not the recommended clearance, but minimum allowable clearance,

j'"-

.............................t

So J

AirShutterAdjustment

This appliance is shipped from the factory with air shutters adjusted for use with Natural Gas. If further adjustment is necessary,or to reset for use with LP, adjustair shutters as follows:

Grill BurnerandSurfaceBurnerCartridgeAir

Shutters(SeeIllustrations"A" & "B')

The left handair shuttercontrolsthe rear halfof the burner,

The right hand shutter controlsthe front half. Access to air shutters on the surface burner cartridge may be found

throughopenings on the bottom of the certridge housing. Slide air shutters backward or forward to increase or

decrease the size of the air opening. Air shutters fit snugly, so a screwdriver blade may be required to make this adjustment (see illustration).

Observe change in flame appearance as the air shutter is moved. Adjustment is satisfactory when a cleady defined, even blue flame results at the high flame setting. The snug fit of the air shutter assures it will remain positioned correctly.

(if SOequipped)

,.o

Grill Burner Air Shutter and Surface Burner

BLADE IN SLOT AND TWIST

 

ALLOW AIR SHUTTER TO

 

WITH SLIGHT PRESSURE TO

 

ILLUSTRATION "A"

 

On any burner, closing the air shutter too far wildcause tile-

_:i'

flame to become soft and yellow tipped. Opening the air

_

shutter too wide will causethe flameto blowaway from the

- .:

burner ports.Properadjustment willproducea sharp,clearly

"

defined, even blue flame.

 

ILLUSTRATION _ _'_-"//

Page 3
Image 3
Jenn-Air JGD8130, JGD8345 InstructionsToInstaller, AirShutterAdjustment, Grill BurnerandSurfaceBurnerCartridgeAir