TO CONVERT APPLIANCE FOR USE WITH PROPANE GAS
Natural Gas To Propane Gas (LP) Conversion Instructions
WARNING
Propane Gas conversion is to be performed by a
WARNING
ELECTRICAL POWER AND GAS MUST BE TURNED OFF PRIOR TO CONVERSION
Models - JGD8348CDP
Manifold - Propane Gas pressure required - 10 W.C.
Incoming Propane Gas pressure required to appliance pressure regulator - 11 - 12 W.C.
Propane Conversion Orifice Hoods are supplied with this model.
Propane Gas input specified - 46,000 BTU/hr.
JGD8348CDP
|
|
| INCHES |
|
BURNER | BTU/hr | ORIFICE | DIAMETER | COLOR |
|
|
|
|
|
Left Rear (LR) | 7500 | #66 | .033 | Zinc |
|
|
|
|
|
Left Front (LF) | 7500 | #66 | .033 | Zinc |
|
|
|
|
|
Center Rear (CR) | 6500 | #68 | .031 | Red |
|
|
|
|
|
Center Front (CF) | 9000 | #63 | .037 | Blue |
|
|
|
|
|
Right Rear (RR) | 6500 | #68 | .031 | Red |
|
|
|
|
|
Right Front (RF) | 9000 | #63 | .037 | Blue |
|
|
|
|
|