Jenn-Air LI3V3A Installation Instructions, Prepare Location, For Cabinet Installations

Models: LI3V3A W10274318A

1 28
Download 28 pages 32.3 Kb
Page 7
Image 7
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Prepare Location

It is recommended that the vent system be installed before hood is installed.

If you are installing an optional backsplash or full width duct cover, follow the instructions included with that product.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

Check your ceiling height and the hood height maximum before you select your hood.

1.Disconnect power.

2.Determine which venting method to use: roof, wall, or non- vented.

3.Select a flat surface for assembling the range hood. Place covering over that surface.

Prepare LocationWARNING

Excessive Weight Hazard

Use two or more people to move and install range hood.

Failure to do so can result in back or other injury.

4.Using 2 or more people, lift range hood onto covered surface.

NOTE: This range hood can be mounted to the cabinets or to the wall.

For Cabinet Installations

1.If cabinet has recessed bottom, add wood filler strips on each side. Install screws to attach filler strips in locations shown.

Wood filler strips (recessed cabinet bottoms only)

3" (7.6 cm)

Cabinet

bottom

3" (7.6 cm)

Wall

Determine Wiring Hole Location

Cut only one 1¹⁄₄" (3.2 cm) diameter wiring access hole. See Step 2 for wiring hole location instructions.

1.Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made.

A For Cabinet Installations

A.Centerline

2.To wire through top:

Mark a line distance “A” from the left of the centerline on the underside of the cabinet. Mark the point on this line that is 7⁷⁄₈" (20.0 cm) from back wall. Drill a 1¼" (3.2 cm) diameter hole through the cabinet at this point.

A

7⁷⁄₈" (20.0 cm)

from wall,

 

not cabinet

 

frame

Centerline

A. 12³⁄₁₆" (31.0 cm)

Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm) Rectangular Vent System

Roof Venting

To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangular cutout on the underside of cabinet top and bottom:

1.Mark lines ³⁄₈" (1.0 cm) and 3⁷⁄₈" (9.8 cm) from the back wall on the centerline of the underside of cabinet.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet.

3.Use saber or keyhole saw to cut a rectangular opening for vent.

7

Page 7
Image 7
Jenn-Air LI3V3A Installation Instructions, Prepare Location, For Cabinet Installations, Determine Wiring Hole Location