Assembly
The dust collector must be disconnected from the power source during assembly. Failure to comply may
result in serious injury!
Motor Housing and Support Canister
1.Place the impeller housing (A, Fig. 1) on the floor with the motor (B, Fig. 1) facing upwards as shown.
2.Attach the fan (C, Fig. 1) to the motor shaft (D, Fig. 1). Allow a
3.Secure the fan (C, Fig. 1) by tightening the hex cap screw on the fan with a 10mm wrench.
4.Attach support cylinder (A, Fig. 2) to the motor housing (B, Fig. 2) with three M6x16 socket head cap screws and three M6 flat washers (C, Fig. 2).
Base Assembly
1.Mount two fixed casters (C, Fig. 3) to the appropriate end of base (D, Fig. 3) using four M6 flat washers (E, Fig. 3), four M6 lock washers (F, Fig. 3) and four M6x12 hex cap bolts (G, Fig. 3).
2.Mount two swivel casters (H, Fig 3) to the appropriate end of the base with two 3/8” hex nuts (I, Fig. 3), four M10 flat washers (J, Fig. 3), and two 3/8” acorn nuts (K, Fig. 3).
Mounting the Support Canister to Base
1.Mount the support canister (L, Fig. 4) to the base (M, Fig. 4) with four M8x12 hex cap bolts and four flat washers (N, Fig. 4).
2.Turn the dust collector over onto the casters.
Note: Make sure the base and housing are relatively parallel. If not loosen the screws that secure the support cylinder to the motor and adjust as necessary. Tighten all hardware.
If you are assembling the
Figure 1
Figure 2
Figure 3
Figure 4
8