2.Slide the tensioning handle (A, Fig.3) onto the shaft and tighten the hex socket set screw.

Electrical Connections

WARNING

All electrical connections must be done by a qualified electrician! Failure to comply may result in serious injury!

￿

WARNING

Disconnect machine from the power source before changing any voltage components! Failure to comply may cause serious injury!

The HBS-1321W bandsaw is rated at 230/460V, 3Ph. and is prewired 230 volt from the factory. Confirm power source available at the saw's location is the same as the saw is wired. To switch the HBS-1321W from 230V to 460V, the following items will have to be changed:

Bandsaw must always be properly grounded.

Main Motor: Follow diagram inside junction box cover.

Coolant Pump: Follow diagram inside junction box cover.

Control Transformer: Open electrical panel on rear of base and switch only the one 230V primary wire on transformer to the 460V position.

Hydraulic Pump: Remove access panel and follow diagram inside junction box cover.

Controls (figure 4)

A.Power Indicator Light: Lit whenever machine has power.

B.Start Button: Depress to start bandsaw. Will not work if emergency button is depressed.

C.Stop Button: Depress to stop bandsaw.

D.Emergency Stop Button: Depress to immediately stop all machine functions.

E.Arm Up Button: Depress to raise arm.

6