4.Remove two screws (D, Fig. 7) and plate (E, Fig. 7).

5.Guide blade through slot in table (A, Fig. 8) and fasten table with two screws (B, Fig. 8).

6.Fasten support bracket to underside of table using screw (C, Fig. 8) and hex nut.

7.Tighten bolt (B, Fig 7).

Electrical Connections

WARNING

All electrical connections￿must be completed

by a qualified electrician.

Failure to comply may cause serious injury!

The HVBS-463 bandsaw is rated at 115/230V and comes from the factory prewired 115V.

To switch to 230V operation, follow the wiring diagram found on the inside of the motor junction box. The plug on the end will have to be replaced with a plug that is rated at 230V.

This bandsaw is designed for use on a circuit with an outlet that looks like (A, Fig. 9). The bandsaw has a grounding prong as illustrated in (B, Fig. 9). A temporary adapter (C, Fig. 9) may be used to connect the plug to a two pole receptacle (D, Fig. 9) if a properly grounded outlet is not available. The temporary adapter should only be used until a properly grounded outlet can be installed by a qualified electrician. The green colored lug must be securely fastened to the cover plate screw.

Before hooking up to the power source, be sure the switch is in the off position.

8

Page 8
Image 8