230 Volt Operation
If 230V, single phase operation is desired, the fol lowing instructions must be followed:
1. Disconnect the machine from the power so urce.
2. Turn the handwheel until the saw blade is in the 45° position. Thiswill all oweasy access to the m otor
junction box.
3. This tablesaw is supplied with four motor leads that are c onnected for 115V operation, as shown in
Figure A. Reconnect these four motor leads for 230V operati on, as shownin F igure B.
4. The 115V attachment plug (A), supplied with the t ablesaw, must be replaced with a UL/CSA listed
plug suitable for 230V operation (D). Contact your local AuthorizedJ ET Service Center or qualified
electrician for proper procedures to instal l the plug. The tablesaw must comply with all local and
national codes after the 230 volt pl ug is installed.
5. The tablesaw with a 230 volt plug should only be connected t o an outlet having the same
configuration (D). No adapter is available or shouldbe used with the 230 v olt plug.
Important: Inal l cases (115 or 230 volts), make certain the recept acle in question is properly grounded.
If you are not sure, have a registered electr ician check the receptacle.