Legend: O = Open (no jumper) C = Closed (jumper on)
Option Settings
Additional drive option jumpers for remote and delayed start are located on the
unit I/O board. They must be set at the factory.
Remote Start
This feature is disabled by default and can be enabled for OEM use.
Delayed Start
This feature is disabled by default and can be enabled for OEM use.
Rear I/O Connections
The rear of the unit and the I/O connections are described below.
FORTRAForce4G6 InstallationGuide Rev B 4-4
Fibre
ID Jmp
0 Jmp
1Jmp
2Jmp
3Jmp
4Jmp
5Jmp
6
100 C C O C C O O
101 O C O C C O O
102 C O O C C O O
103 O O O C C O O
104 C C C O C O O
105 O C C O C O O
106 C O C O C O O
107 O O C O C O O
108 C C O O C O O
109 O C O O C O O
110 C 0 O O C O O
111 O 0 O O C O O
112 C C C C O O O
113 O C C C O O O
114 C 0 C C O O O
115 O 0 C C O O O
116 C C O C O O O
117 O C O C O O O
118 C O O C O O O
119 OOOCOOO
120 C C C O O O O
121 O C C O O O O
122 C O C O O O O
123 OOCOOOO
124 CCOOOOO
125 OCOOOOO
126 COOOOOO
127 OOOOOOO