Technical data

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

SUPPLY CONNECTIONS

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Heating Elements Rating

Rear Left Burner (semi rapid)

Heat Input

2.0 kW

Front Left

Burner (rapid)

Heat Input

3.0 kW

Rear Right Burner (semi rapid)

Heat Input

2.0 kW

Front Right Burner (auxiliary)

Heat Input

1.0 kW

TYPE OF G A S

CHARACTERISTICS

BURNER

RAPID

SEMI-RAPID

AUXILIARY

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

3

NOMINAL THERMAL

 

 

 

 

 

 

NATURAL GAS

 

VALUE= 37.78 MJ/m Ws - 50.7 MJ/ m3

 

 

 

 

 

 

20 mbar

POWER

kW

3.0

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

RATE

m3/h

0.286

0.057

0.190

0.043

0.095

0.028

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-30/37 mbar

VALUE = 49.92 MJ/Kg

NOMINAL THERMAL

 

 

 

 

 

 

LPG GAS

POWER

kW

2.8

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

RATE

g/h

202

47

144

32

72

24

NOZZLE REFERENCE

86

40

71

32

50

28

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

 

 

Auxiliary

28

Semi-rapid

32

Rapid40

Aeration adjustment none

APPLIANCE CLASS: 3

APPLIANCE CATEGORY: II2H3+

APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar